Goodman GMS80904BN Gas Furnace Manual

The Goodman GMS80904BN is a high-efficiency gas furnace with 80% AFUE rating, single-stage operation, multi-speed blower, and compatibility with standard thermostat systems. Designed for residential use with natural gas, it features electronic ignition, aluminized steel heat exchanger, and safety controls including flame rollout and limit switches. Below are key sections for safety, installation, operation, maintenance, and troubleshooting.

1. Safety Information 2. Installation Requirements 3. Technical Specifications 4. Control System Overview 5. Venting and Combustion Air 6. Electrical Connections 7. Startup and Operation 8. Maintenance Procedures 9. Troubleshooting Guide 10. Warranty Information

Safety Information

Critical safety precautions for installation and operation.

HazardPrecaution
Gas LeaksInstall gas leak detector; check all connections with soap solution
Carbon MonoxideInstall CO detectors; ensure proper venting
Electrical ShockDisconnect power before servicing
Fire HazardKeep combustible materials away from furnace
Burn RiskAllow furnace to cool before servicing

WARNING! Installation must be performed by qualified HVAC technician only.

Installation Requirements

Proper installation guidelines and requirements.

  1. Location: Install in clean, dry area with adequate clearance (minimum 24" front, 6" sides)
  2. Gas Supply: 3/4" black iron pipe with sediment trap; test for leaks
  3. Electrical: 120V AC, 15 amp dedicated circuit with proper grounding
  4. Venting: Category I venting; follow local codes for vent pipe sizing
  5. Combustion Air: Ensure adequate fresh air supply per installation requirements

CAUTION! Improper installation may create hazardous conditions.

Technical Specifications

Control System Overview

Integrated furnace control board with LED status indicator.

ComponentFunction
Control BoardMain system controller with diagnostic codes
Gas ValveRegulates gas flow to burners
IgniterHot surface igniter for burner ignition
Flame SensorDetects burner flame presence
Pressure SwitchVerifies inducer operation
Limit SwitchPrevents overheating
Rollout SwitchDetects flame rollout condition

Venting and Combustion Air

Proper venting system requirements for safe operation.

  1. Vent Pipe: Use approved Category I vent material; maintain proper slope
  2. Termination: Roof or sidewall vent per local codes; maintain clearances
  3. Combustion Air: Provide adequate air supply; follow manufacturer guidelines
  4. Vent Length: Maximum equivalent vent length: 40 feet with two 90° elbows

WARNING! Inadequate venting can cause carbon monoxide poisoning.

Electrical Connections

Wiring and electrical connection requirements.

  1. Power Supply: 115V AC, 60 Hz, properly grounded circuit
  2. Thermostat: Standard 24V connections (R, W, G, C, Y)
  3. Blower Speeds: Adjustable cooling and heating speeds
  4. Safety Switches: Properly wire door safety switch

CAUTION! All electrical work must comply with NEC and local codes.

Startup and Operation

Proper startup sequence and normal operation.

  1. Power On: Restore electrical power to furnace
  2. Thermostat Call: Set thermostat above room temperature
  3. Ignition Sequence: Inducer motor starts, pressure switch closes, igniter heats, gas valve opens
  4. Flame Detection: Flame sensor confirms ignition, main burners operate
  5. Blower Operation: Blower starts after warm-up delay
  6. Cycle Completion: Furnace shuts down when thermostat satisfied

Maintenance Procedures

Regular maintenance schedule and procedures.

Maintenance ItemFrequencyProcedure
Air FilterMonthlyReplace or clean filter
Burner InspectionAnnuallyClean burners and inspect flame pattern
Heat ExchangerAnnuallyVisual inspection for cracks or damage
Blower AssemblyAnnuallyClean blower wheel and housing
Vent SystemAnnuallyInspect for obstructions or damage

Troubleshooting Guide

SymptomPossible CauseCorrective Action
No heatThermostat setting, power, gas supplyCheck thermostat, circuit breaker, gas valve
Furnace won't startDoor switch, limit switch, pressure switchEnsure door closed, check switch continuity
Short cyclingDirty filter, blocked vent, overheatingReplace filter, check venting, verify airflow
Blower runs continuouslyThermostat fan setting, control boardCheck thermostat fan setting, control board
Lockout conditionIgnition failure, flame senseReset power, check igniter and flame sensor

LED Error Codes: Refer to control board LED flash patterns for specific diagnostics.

Warranty Information

Goodman limited warranty coverage.

For warranty service, contact authorized Goodman dealer. Keep original sales receipt and installation date.

Technical Support: 1-877-GOODMAN | www.goodmanmfg.com

Goodman GMS80904BN Gas Furnace Manual © - All Rights Reserved 2025