Goodman Janitrol Furnace Manual

The Goodman Janitrol furnace is a high-efficiency gas furnace designed for residential heating applications. This manual covers installation, operation, maintenance, and troubleshooting for various Goodman Janitrol furnace models. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Components 7. Operation 8. Maintenance Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Gas valve, heat exchanger, blower motor, ignition system, thermostat connection, pressure switches, limit switches.

FeatureDescription
Gas valveControls gas flow to burners
Heat exchangerTransfers heat from combustion to air
Blower motorCirculates heated air through ductwork
Ignition systemElectronic ignition for reliable startup
Thermostat connectionFor temperature control input
Pressure switchesSafety device for venting system
Limit switchesPrevents overheating
Filter accessEasy filter replacement
Diagnostic lightsLED indicators for troubleshooting
Service portsFor pressure testing and service

Installation

Unpack and inspect contents. Ensure proper location and clearances.

  1. Select location: Choose area with proper clearances and ventilation.
  2. Gas connection: Use approved gas piping and fittings.
  3. Electrical connection: Connect to proper voltage supply with disconnect.
  4. Vent system: Install approved vent piping according to codes.
  5. Ductwork: Connect supply and return ducts properly.

WARNING! Gas appliances can be dangerous; follow all safety codes. Professional installation recommended.

First-Time Setup

Power on furnace; follow startup procedure.

  1. Check gas supply: Ensure gas valve is open and gas is available.
  2. Electrical power: Turn on disconnect switch and verify power.
  3. Thermostat setup: Set thermostat to heating mode and desired temperature.
  4. Initial startup: System will go through ignition sequence.
  5. Verify operation: Check for proper heating and airflow.

CAUTION! Ensure proper ventilation and clearances before operation.

Specifications

Controls and Settings

Access control board via front panel. Integrated control module with diagnostic capabilities.

Thermostat: HEAT/COOL/OFF, FAN AUTO/ON, temperature setting, system switch.

Control Board: Power switch, diagnostic LED, dip switches for configuration. Settings: Fan speed, temperature rise, timing sequences. Safety: Limit switches, pressure switches, rollout switches. Diagnostic: LED flash codes for troubleshooting.

Connecting Components

Thermostat: Low voltage connections. Gas line: Black iron or CSST. Electrical: 120V supply. Vent: PVC piping. Ductwork: Supply and return connections.

  1. Turn off power and gas before connecting.
  2. Match wires to terminal designations (R, W, G, Y, C).
  3. Use proper pipe dope and thread sealant for gas connections.
  4. Ensure vent piping is properly sloped and supported.

Tip: Always verify connections with manufacturer's wiring diagram.

Operation

Heating cycle sequence and normal operation.

  1. Call for heat: Thermostat signals furnace to start.
  2. Inducer motor: Starts to prove draft and clear combustion chamber.
  3. Ignition: Hot surface igniter glows and gas valve opens.
  4. Burner operation: Flame is established and verified.
  5. Blower operation: Blower starts after heat exchanger warms up.
  6. Cycle completion: Thermostat satisfied, gas valve closes, blower continues.
  7. Safety shutdown: System monitors for unsafe conditions.

WARNING! Never bypass safety devices. Service by qualified technician only.

Maintenance Features

Filter replacement: Monthly inspection, replace as needed. Annual maintenance: Professional inspection and cleaning recommended. Diagnostic codes: LED flash patterns indicate specific issues.

Care & Cleaning

Turn off power before servicing. Clean burners and heat exchanger annually. Replace air filter regularly.

CAUTION! Do not operate without filter. Keep combustion area clear of debris.

Regulatory Information

ANSI Z21.47: Certified for safety standards. UL listed: Meets electrical safety requirements. Local codes: Installation must comply with all applicable building codes. For support, visit www.goodmanmfg.com or contact 1-877-466-8626.

Troubleshooting

SymptomPossible CauseCorrective Action
No heatThermostat/power/gasCheck thermostat setting; verify power and gas supply; check filter.
Furnace not startingSafety lockoutCheck diagnostic LED; reset power; verify venting.
Short cyclingDirty filter/overheatingReplace filter; check airflow; verify temperature rise.
Blower not runningMotor/control issueCheck blower door switch; verify motor operation; check capacitor.
Unusual noisesMechanical issuesInspect blower wheel; check heat exchanger; verify inducer motor.

Reset: Power cycle if locked out. Check diagnostic codes for specific issues.

Service: 1-877-466-8626; www.goodmanmfg.com