The Guardian Furnace BCU05010A is a high-efficiency gas furnace with 50,000 BTU output capacity, electronic ignition system, variable-speed blower motor, multi-speed operation, built-in diagnostic LED, safety shut-off features, and compatibility with standard thermostat systems. Designed for residential use with natural gas or propane conversion capability. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Gas valve assembly, heat exchanger, blower motor, igniter, flame sensor, pressure switches, diagnostic LED, filter compartment.
| Feature | Description |
|---|---|
| Gas valve | For natural gas or propane operation |
| Heat exchanger | Stainless steel primary and secondary |
| Blower motor | Variable speed ECM motor |
| Ignition system | Hot surface igniter |
| Flame sensor | Safety flame detection |
| Pressure switches | Induced draft safety |
| Diagnostic LED | Error code display |
| Filter compartment | Standard 1-inch filter |
| Power switch | Unit on/off control |
| Gas connection | 1/2" NPT gas inlet |
Unpack and inspect all components. Ensure proper clearances and ventilation.
WARNING! Installation must be performed by qualified HVAC technician. Gas leaks can cause explosion or fire.
Power on furnace; follow startup sequence.
CAUTION! Never bypass safety devices. Ensure proper ventilation during operation.
Access control board via front panel. LED indicator shows operational status.
Control Board: Power switch, diagnostic LED, thermostat terminals, gas valve connector.
Operation sequence: Thermostat call for heat, inducer motor starts, pressure switch confirms, igniter heats, gas valve opens, flame sensor confirms, blower starts after delay. Diagnostic codes: Steady green = normal operation, flashing codes indicate specific faults.
Standard 24V thermostat connection with R, W, G, C terminals.
Tip: Ensure thermostat is located away from heat sources and drafts.
Regular maintenance ensures optimal performance and safety.
WARNING! Always turn off power and gas supply before performing maintenance.
Multiple safety systems: Flame rollout switch, high limit switch, pressure switches, flame sensor, igniter safety lockout.
Turn off power before cleaning. Use soft brush and vacuum for dust removal.
CAUTION! Never use water or cleaning chemicals on electrical components. Keep area around furnace clear of combustible materials.
UL certified for safety standards. ANSI Z21.47 compliant for gas appliances. CSA certified for Canadian standards. Manufactured to meet DOE efficiency requirements. For technical support, contact Guardian Heating & Cooling at 1-800-555-HEAT or visit www.guardianheating.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power/thermostat | Check circuit breaker; verify thermostat settings; ensure door switch engaged. |
| No heat | Gas supply/ignition | Verify gas valve open; check for ignition failure; inspect flame sensor. |
| Short cycling | Airflow/filter | Replace dirty filter; check for blocked vents; verify proper airflow. |
| Blower not running | Motor/control | Check blower motor operation; verify control board signals; inspect capacitor. |
| Error code flashing | System fault | Refer to diagnostic chart; count LED flashes for specific error code. |
Reset: Turn power off for 30 seconds, then restart.
Service: 1-800-555-HEAT; www.guardianheating.com