The Guardian GGLs080B12MP11A is an 80,000 BTU high-efficiency gas furnace designed for residential heating applications. This natural gas furnace features multi-speed blower operation, electronic ignition, safety shut-off controls, and compatibility with standard thermostat systems. Below are key sections covering safety, installation, operation, maintenance, and troubleshooting.
Key components: Multi-speed direct drive blower, hot surface ignition, aluminized steel heat exchanger, integrated control board, pressure switches, flame sensor, and limit controls.
| Feature | Description |
|---|---|
| Heating Capacity | 80,000 BTU/H input |
| Efficiency Rating | 80% AFUE |
| Blower Motor | Multi-speed PSC |
| Ignition System | Hot surface electronic ignition |
| Gas Type | Natural gas |
| Venting | Category I vertical or horizontal |
| Electrical Requirements | 120V AC, 60Hz |
| Control Voltage | 24V AC |
| Filter Size | 16x25x1 inch |
| Warranty | 20-year heat exchanger limited warranty |
Professional installation required. Ensure proper clearances and local code compliance.
WARNING! Gas appliances can produce carbon monoxide. Proper installation and venting are critical for safety. Installation must comply with local codes and NFPA 54.
Complete installation verification before initial startup.
CAUTION! Only qualified HVAC technicians should perform installation and startup procedures.
Integrated control board manages all furnace operations with LED status indicator.
Control Board LED Codes: Steady ON = Normal operation; 1 Flash = Pressure switch error; 2 Flashes = Ignition lockout; 3 Flashes = Limit circuit lockout; 4 Flashes = Flame sense error.
Thermostat Operation: Connect standard 24V thermostat to R, W, G terminals. System operates on call for heat from thermostat.
Blower Speeds: Adjust blower speed taps for proper airflow (COOL, HEAT LOW, HEAT HIGH).
Category I venting system required. Ensure proper combustion air supply.
Tip: Install carbon monoxide detectors in sleeping areas and near furnace location.
Regular maintenance ensures optimal performance and safety.
WARNING! Turn off electrical power and gas supply before performing any maintenance.
Keep furnace area clean and free of combustible materials.
Air Filter: Replace 1-inch disposable filter every 1-3 months during heating season.
Exterior: Wipe with damp cloth only; do not use chemical cleaners.
Vent Terminal: Keep clear of snow, leaves, and debris.
CAUTION! Do not attempt to clean internal components without proper training. Contact qualified technician.
ANSI Z21.47/CSA 2.3: Certified for natural gas operation. UL listed. Installation must comply with National Fuel Gas Code NFPA 54/ANSI Z223.1 and local building codes. For technical support, contact Guardian Customer Service at 1-800-XXX-XXXX or visit www.guardianheating.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat setting, ensure door properly closed. |
| No heat | Gas supply, ignition | Verify gas valve on, check for ignition attempts, inspect flame sensor. |
| Short cycling | Dirty filter, airflow | Replace air filter, check for blocked vents or registers. |
| Blower won't stop | Thermostat fan setting | Check thermostat fan setting (should be AUTO, not ON). |
| Unusual noises | Blower, ductwork | Inspect blower wheel, check for loose panels or duct connections. |
| Lockout condition | Safety controls | Reset power, check LED error code, call for service if persistent. |
Reset Procedure: Turn thermostat to lowest setting, turn off power for 30 seconds, restore power, set thermostat to desired temperature.
Service: 1-800-XXX-XXXX; www.guardianheating.com