Heat Controller Furnace Manual

The Heat Controller Furnace is a high-efficiency heating system designed for residential use, featuring advanced temperature control, multiple heating stages, energy-saving modes, built-in safety features, digital thermostat interface, filter monitoring system, and compatibility with various venting options. Powered by standard household electrical supply with natural gas or propane fuel sources. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Thermostat 7. Operating Modes 8. Safety Features 9. Maintenance & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: High-efficiency heat exchanger, Digital control board, Blower motor, Gas valve, Ignition system, Filter compartment, Thermostat connections, Safety switches.

FeatureDescription
Digital control boardManages all furnace operations and diagnostics
Multi-speed blower motorVariable speed for optimal airflow and efficiency
Electronic ignitionReliable spark ignition system
Filter monitoring systemAlerts when filter needs replacement
Safety shut-off switchesHigh-limit and rollout protection
Thermostat connectionsCompatible with most digital thermostats
POWER switchMain power control
Diagnostic LEDDisplays error codes for troubleshooting
Gas valvePrecise fuel control
Vent connectionsPVC venting compatible

Installation

Unpack and inspect all components. Ensure proper location with adequate clearance.

  1. Position furnace: Place on stable, level surface with proper clearances.
  2. Connect gas line: Use approved gas piping and fittings; pressure test required.
  3. Connect electrical: Follow local electrical codes; proper grounding essential.
  4. Install venting: Use approved PVC vent pipes with proper slope.
  5. Connect thermostat: Use low-voltage wiring per diagram.
  6. Install air filter: Insert proper size filter in filter compartment.

WARNING! Installation must be performed by qualified technician. Gas leaks can cause explosion. Follow all local codes.

First-Time Setup

Power on furnace; follow startup sequence.

  1. Verify gas connection: Check for leaks with soap solution.
  2. Set thermostat: Program desired temperature settings.
  3. Test operation: Run through complete heating cycle.
  4. Adjust blower speed: Set for optimal airflow if adjustable.
  5. Configure filter reminder: Set replacement interval.

CAUTION! Ensure proper ventilation. Test carbon monoxide detectors.

Specifications

Controls and Settings

Access control board via front panel. Diagnostic LED displays status codes.

Thermostat Controls: Temperature setting, Fan mode (Auto/On), System mode (Heat/Off), Program schedules.

Furnace Settings: Blower speed adjustments, Filter timer reset, Diagnostic mode access, Gas pressure adjustment (qualified technician only). Safety: High-limit settings, Ignition retry attempts, Pressure switch monitoring, Flame sensor monitoring.

Connecting Thermostat

Compatible with most 24VAC thermostats. Standard connections: R, W, G, Y, C.

  1. Turn off power to furnace before wiring.
  2. Match thermostat wires to control board terminals.
  3. Use proper low-voltage thermostat wire.
  4. Secure connections and replace access panel.
  5. Restore power and test operation.

Tip: Use programmable thermostat for maximum energy savings.

Operating Modes

Multiple operating modes for efficiency and comfort.

  1. Heating Mode: Primary heating operation with variable output.
  2. Fan Only: Circulates air without heat.
  3. Standby: Ready state waiting for heat demand.
  4. Diagnostic: Service mode for troubleshooting.
  5. Lockout: Safety shutdown with error code display.

WARNING! Do not attempt to override safety lockouts. Contact qualified service technician.

Safety Features

Multiple safety systems protect against hazardous conditions.

Safety FeatureFunction
Flame rollout switchDetects improper burner operation
High limit switchPrevents overheating
Pressure switchesEnsures proper venting
Flame sensorConfirms burner ignition
Gas valveAutomatic shut-off if no ignition
Ignition controlLimited retry attempts

Maintenance & Cleaning

Regular maintenance ensures optimal performance and safety.

  1. Monthly: Check and replace air filter as needed.
  2. Annual: Professional inspection and cleaning.
  3. Seasonal: Check vent pipes for obstructions.
  4. As needed: Clean flame sensor and burners.

CAUTION! Turn off power and gas supply before servicing. Only qualified technicians should perform internal maintenance.

Regulatory Information

UL certified: Meets UL 1995 standards for heating and cooling equipment. ANSI compliance: Meets ANSI Z21.47 standards for gas-fired central furnaces. EPA compliant: Meets emissions standards for residential heating equipment. For support, visit www.heatcontroller.com or contact 1-800-HEAT-CTL. Manufactured under license and patents.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower, thermostat, switchCheck power supply; verify thermostat settings; ensure door switch engaged.
No heatGas supply, ignitionVerify gas valve on; check pilot/ignition; review error codes.
Short cyclingFilter, limit switchReplace dirty filter; check for blocked vents; verify proper airflow.
Blower doesn't runMotor, capacitor, boardCheck blower motor; test capacitor; verify control board signals.
Error code flashingVarious faultsRefer to diagnostic chart in service manual; reset if safe.
Gas odorLeak, improper combustionImmediately shut off gas; evacuate area; contact professional.

Reset: Power cycle furnace if safe. Some errors require professional reset.

Service: 1-800-HEAT-CTL; www.heatcontroller.com

Heat Controller Furnace Manual © - All Rights Reserved 2025