Holly Furnace Manual

The Holly Furnace is a high-efficiency heating system designed for residential and light commercial use. This manual covers the Holly Series furnace models with advanced combustion technology, electronic ignition, variable-speed blower motor, built-in diagnostics, safety controls, and compatibility with standard thermostat systems. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Thermostat 7. Operating Procedures 8. Maintenance Schedule 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Heat exchanger, blower assembly, gas valve, electronic ignition, filter compartment, pressure switches, control board, vent connections.

FeatureDescription
Heat exchangerStainless steel tubular design for high efficiency
Blower assemblyVariable-speed ECM motor for quiet operation
Gas valveElectronic modulation for precise gas flow control
Electronic ignitionHot surface igniter for reliable startup
Filter compartmentStandard 1-inch or 4-inch media filter compatible
Pressure switchesSafety verification of proper venting
Control boardLED diagnostic indicators and system controls
Vent connectionsPVC pipe compatible for direct vent installation
Thermostat terminalsStandard R, W, Y, G, C connections
Service switchExternal power disconnect for safety

Installation

Unpack and inspect all components. Ensure proper clearances and level mounting surface.

  1. Position furnace: Place on stable, level surface with proper clearances (6 inches minimum from combustible materials).
  2. Connect gas supply: Use black iron pipe with proper thread sealant. Pressure test for leaks.
  3. Connect electrical: 120V AC power supply with dedicated circuit. Connect thermostat wiring.
  4. Install venting: Use approved PVC pipe for intake and exhaust. Maintain proper slope.
  5. Connect ductwork: Secure supply and return air ducts with proper sealing.

WARNING! Gas appliances can be dangerous; installation must comply with local codes and be performed by qualified technician.

First-Time Setup

Complete installation checks before initial startup.

  1. Verify gas connections: Check for leaks with soap solution.
  2. Check electrical: Ensure proper voltage and grounding.
  3. Install air filter: Insert clean filter in designated compartment.
  4. Set thermostat: Program desired temperature settings.
  5. Startup sequence: Turn on gas supply, then electrical power.
  6. Test operation: Verify proper ignition and heating cycle.

CAUTION! Never operate without proper venting and air filter installed.

Specifications

Controls and Settings

Access control board via front panel. LED indicators show system status and error codes.

Control Board: POWER, STATUS LED (green=normal, red=fault), RESET button, DIP switches for configuration.

Thermostat Settings: HEAT/COOL mode, FAN AUTO/ON, temperature setpoints. Blower Settings: Adjustable delay timers for fan on/off. Gas Valve: Electronic modulation for precise temperature control. Safety Controls: Limit switches, pressure switches, flame sensor, rollout switches.

Connecting Thermostat

Standard 5-wire thermostat connection: R (24V power), W (heat), Y (cool), G (fan), C (common).

  1. Turn off power to furnace before wiring.
  2. Strip thermostat wires 1/4 inch.
  3. Connect to corresponding terminals on control board.
  4. Secure connections and replace access panel.
  5. Restore power and test thermostat operation.

Tip: Use compatible programmable thermostat for optimal efficiency.

Operating Procedures

Normal heating cycle operation and seasonal startup.

  1. Set thermostat to desired temperature in HEAT mode.
  2. Furnace initiates: Inducer motor starts, pressure switch verifies, igniter heats.
  3. Gas valve opens: Flame established, flame sensor confirms.
  4. Blower starts: After heat exchanger warm-up delay.
  5. Cycle complete: Thermostat satisfied, gas valve closes, blower continues cooling.
  6. Seasonal shutdown: Turn off gas supply if not used for extended periods.

WARNING! Never bypass safety controls or operate with access panels removed.

Maintenance Schedule

Regular maintenance ensures optimal performance and safety.

FrequencyMaintenance Task
MonthlyCheck/change air filter
SeasonalInspect vent system for obstructions
AnnualProfessional inspection and cleaning
AnnualCheck gas pressure and combustion
AnnualClean flame sensor and heat exchanger
AnnualLubricate blower motor if required

Care & Cleaning

Turn off power and gas supply before cleaning. Use soft brush and vacuum for internal components.

CAUTION! Never use water or chemical cleaners on electrical components. Keep area around furnace clear of combustible materials.

Regulatory Information

UL certified for safety standards. ANSI Z21.47 compliant for gas appliances. Meets DOE efficiency requirements. Manufactured to comply with all applicable federal and state regulations. For technical support, contact Holly Furnace Customer Service at 1-800-555-HEAT or visit www.hollyfurnace.com.

Troubleshooting

SymptomPossible CauseCorrective Action
No heatThermostat setting, power, gas supplyCheck thermostat, circuit breaker, gas valve position
Furnace won't startSafety lockout, limit switchReset power, check error codes, verify filter clean
Short cyclingDirty filter, blocked ventReplace filter, check vent pipes for obstructions
Blower not workingMotor, capacitor, control boardCheck power to blower, test capacitor, verify control signals
Gas odorGas leakImmediately shut off gas supply and contact professional

Reset Procedure: Turn off power for 30 seconds, then restore.

Service: 1-800-555-HEAT; www.hollyfurnace.com