Honeywell Furnace Control Board Manual

The Honeywell Furnace Control Board is a sophisticated electronic control system designed for residential and commercial furnace applications. It features integrated safety controls, diagnostic LED indicators, multi-stage heating capability, blower motor control, flame sensor monitoring, and compatibility with various thermostat systems. Below are key sections covering installation, operation, troubleshooting, and maintenance procedures.

1. Features at a Glance 2. Installation Guidelines 3. Wiring Configuration 4. Technical Specifications 5. Control Board Operation 6. Diagnostic Indicators 7. Safety Features 8. Maintenance Procedures 9. Regulatory Compliance 10. Troubleshooting Guide

Features at a Glance

Key components: Main control processor, LED status indicators, terminal blocks, fuse protection, transformer connections, gas valve control, inducer motor control, and blower motor outputs.

FeatureDescription
LED Status IndicatorsProvides visual diagnostic codes for troubleshooting
Multi-stage HeatingSupports single and two-stage furnace operation
Blower ControlVariable speed blower motor management
Flame Sensor InputMonitors flame presence for safety shutdown
Pressure Switch InputsVerifies proper venting operation
Thermostat ConnectionsCompatible with conventional and smart thermostats
Limit Circuit ProtectionPrevents overheating conditions
Fuse Protection3A fuse for circuit protection
Transformer Input24VAC power input connection
Gas Valve ControlManages gas valve operation sequences

Installation Guidelines

Proper installation ensures safe and efficient furnace operation. Follow all local codes and manufacturer specifications.

  1. Power Disconnect: Turn off electrical power and gas supply before installation.
  2. Board Mounting: Secure control board using provided mounting holes and standoffs.
  3. Wiring Connection: Route wires through appropriate strain relief and connect to proper terminals.
  4. Gas Valve Connection: Connect gas valve control wires to designated terminals.
  5. Transformer Connection: Connect 24VAC transformer leads to proper input terminals.

WARNING! Only qualified HVAC technicians should install or service this control board. Incorrect installation can cause fire, explosion, or carbon monoxide poisoning.

Wiring Configuration

Refer to wiring diagram included with control board for specific terminal assignments.

  1. Thermostat Connections: R (24V), W/W1/W2 (Heat), G (Fan), C (Common)
  2. Blower Motor: Connect to appropriate speed taps for heating and cooling operation
  3. Inducer Motor: Connect inducer relay output to inducer motor
  4. Pressure Switches: Connect normally open pressure switch contacts
  5. Flame Sensor: Connect micro-amp flame sensor input
  6. Gas Valve: Connect gas valve output terminals

CAUTION! Verify all connections are secure and properly insulated. Use wire nuts or terminal blocks as required.

Technical Specifications

Control Board Operation

The control board follows a specific ignition sequence for safe furnace operation.

Normal Heating Sequence: Thermostat call for heat → Inducer motor starts → Pressure switch verification → Hot surface igniter heats → Gas valve opens → Flame detection → Blower motor starts → Continuous operation until thermostat satisfied

LED Indicators: Solid green = normal operation, Flashing codes = diagnostic information, No light = no power or board failure.

Diagnostic Indicators

LED flash patterns indicate specific operational status and fault conditions.

Flash PatternDescriptionAction Required
1 FlashPressure switch stuck openCheck inducer, venting, pressure switch
2 FlashesPressure switch stuck closedReplace pressure switch
3 FlashesIgnition failureCheck gas supply, igniter, flame sensor
4 FlashesLimit circuit lockoutCheck airflow, filters, limit switches
5 FlashesFlame sense failureClean flame sensor, check grounding
6 FlashesRollout switch openCheck heat exchanger, venting
7 FlashesGas valve circuit faultCheck gas valve wiring and voltage

Safety Features

Multiple safety systems protect against hazardous conditions.

  1. Flame Rollout Protection: Rollout switches detect improper combustion
  2. High Limit Protection: Temperature limits prevent overheating
  3. Pressure Switch Monitoring: Ensures proper venting before ignition
  4. Flame Detection: Confirms flame presence within trial for ignition period
  5. Fuse Protection: Prevents electrical overload damage
  6. Lockout Protection: Prevents continuous ignition attempts

WARNING! Never bypass safety devices. Replace faulty components immediately.

Maintenance Procedures

Regular maintenance ensures optimal performance and longevity.

  1. Annual Inspection: Check all electrical connections for tightness
  2. Flame Sensor Cleaning: Clean with fine emery cloth annually
  3. Filter Replacement: Replace air filters monthly during heating season
  4. Venting Inspection: Check vent pipes for obstructions or damage
  5. Electrical Testing: Verify proper voltages at all terminals
  6. Gas Pressure Check: Verify correct manifold gas pressure

CAUTION! Always disconnect power before performing maintenance.

Regulatory Compliance

This control board complies with UL Standard 60730-1, ANSI Z21.47, and CSA C22.2 No. 199. Installation must comply with National Fuel Gas Code (NFPA 54), National Electrical Code (NFPA 70), and all local building codes. For technical support, contact Honeywell Customer Support at 1-800-468-1502 or visit www.honeywell.com/homes.

Troubleshooting Guide

SymptomPossible CauseCorrective Action
No heatPower loss, thermostat issueCheck circuit breaker, thermostat settings, transformer
Furnace short cyclesDirty filter, blocked ventReplace filter, check venting, verify airflow
Blower won't startMotor failure, capacitor issueCheck blower motor, capacitor, control board output
Igniter doesn't glowFailed igniter, wiring issueTest igniter continuity, check wiring connections
Gas valve doesn't openValve failure, pressure switchVerify 24V at valve, check pressure switch operation
LED flashing error codeSpecific fault conditionRefer to diagnostic chart for specific flash pattern

Reset Procedure: Turn power off for 30 seconds, then restore power to reset control board.

Technical Support: 1-800-468-1502; www.honeywell.com/homes