The Honeywell Furnace Control Board is a sophisticated electronic control system designed for residential and commercial furnace applications. It features integrated safety controls, diagnostic LED indicators, multi-stage heating capability, blower motor control, flame sensor monitoring, and compatibility with various thermostat systems. Below are key sections covering installation, operation, troubleshooting, and maintenance procedures.
Key components: Main control processor, LED status indicators, terminal blocks, fuse protection, transformer connections, gas valve control, inducer motor control, and blower motor outputs.
| Feature | Description |
|---|---|
| LED Status Indicators | Provides visual diagnostic codes for troubleshooting |
| Multi-stage Heating | Supports single and two-stage furnace operation |
| Blower Control | Variable speed blower motor management |
| Flame Sensor Input | Monitors flame presence for safety shutdown |
| Pressure Switch Inputs | Verifies proper venting operation |
| Thermostat Connections | Compatible with conventional and smart thermostats |
| Limit Circuit Protection | Prevents overheating conditions |
| Fuse Protection | 3A fuse for circuit protection |
| Transformer Input | 24VAC power input connection |
| Gas Valve Control | Manages gas valve operation sequences |
Proper installation ensures safe and efficient furnace operation. Follow all local codes and manufacturer specifications.
WARNING! Only qualified HVAC technicians should install or service this control board. Incorrect installation can cause fire, explosion, or carbon monoxide poisoning.
Refer to wiring diagram included with control board for specific terminal assignments.
CAUTION! Verify all connections are secure and properly insulated. Use wire nuts or terminal blocks as required.
The control board follows a specific ignition sequence for safe furnace operation.
Normal Heating Sequence: Thermostat call for heat → Inducer motor starts → Pressure switch verification → Hot surface igniter heats → Gas valve opens → Flame detection → Blower motor starts → Continuous operation until thermostat satisfied
LED Indicators: Solid green = normal operation, Flashing codes = diagnostic information, No light = no power or board failure.
LED flash patterns indicate specific operational status and fault conditions.
| Flash Pattern | Description | Action Required |
|---|---|---|
| 1 Flash | Pressure switch stuck open | Check inducer, venting, pressure switch |
| 2 Flashes | Pressure switch stuck closed | Replace pressure switch |
| 3 Flashes | Ignition failure | Check gas supply, igniter, flame sensor |
| 4 Flashes | Limit circuit lockout | Check airflow, filters, limit switches |
| 5 Flashes | Flame sense failure | Clean flame sensor, check grounding |
| 6 Flashes | Rollout switch open | Check heat exchanger, venting |
| 7 Flashes | Gas valve circuit fault | Check gas valve wiring and voltage |
Multiple safety systems protect against hazardous conditions.
WARNING! Never bypass safety devices. Replace faulty components immediately.
Regular maintenance ensures optimal performance and longevity.
CAUTION! Always disconnect power before performing maintenance.
This control board complies with UL Standard 60730-1, ANSI Z21.47, and CSA C22.2 No. 199. Installation must comply with National Fuel Gas Code (NFPA 54), National Electrical Code (NFPA 70), and all local building codes. For technical support, contact Honeywell Customer Support at 1-800-468-1502 or visit www.honeywell.com/homes.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Power loss, thermostat issue | Check circuit breaker, thermostat settings, transformer |
| Furnace short cycles | Dirty filter, blocked vent | Replace filter, check venting, verify airflow |
| Blower won't start | Motor failure, capacitor issue | Check blower motor, capacitor, control board output |
| Igniter doesn't glow | Failed igniter, wiring issue | Test igniter continuity, check wiring connections |
| Gas valve doesn't open | Valve failure, pressure switch | Verify 24V at valve, check pressure switch operation |
| LED flashing error code | Specific fault condition | Refer to diagnostic chart for specific flash pattern |
Reset Procedure: Turn power off for 30 seconds, then restore power to reset control board.
Technical Support: 1-800-468-1502; www.honeywell.com/homes