Hydro Flame Furnace Owners Manual

The Hydro Flame Furnace is a high-efficiency heating system designed for residential and light commercial use, featuring advanced combustion technology, digital temperature control, safety shut-off systems, energy-saving modes, and easy maintenance access. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to HVAC System 7. Operating Procedures 8. Safety Features 9. Maintenance & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, combustion chamber, heat exchanger, blower assembly, gas valve, ignition system, safety sensors.

FeatureDescription
Digital Control PanelLCD display with temperature settings and system status
High-Efficiency Heat ExchangerStainless steel construction for optimal heat transfer
Variable Speed BlowerAutomatically adjusts airflow for efficiency
Electronic IgnitionPilotless ignition for energy savings
Safety Shut-off SystemAutomatic shutdown if issues detected
Energy Saving ModeReduces energy consumption during low demand
Maintenance AlertNotifies when service is required
Remote Control CompatibleWorks with optional thermostat systems
Multi-stage OperationAdapts heating output to demand
Quiet OperationSound-dampening technology

Installation

Unpack and inspect contents. Ensure proper location with adequate clearance.

  1. Select installation location: Minimum 18" clearance on all sides, away from combustible materials.
  2. Connect to gas supply: Use approved gas piping; check for leaks with soap solution.
  3. Connect to electrical: 120V AC power supply with proper grounding.
  4. Connect to ductwork: Secure all connections with approved tape or sealant.
  5. Install venting: Follow local codes for proper exhaust and intake vent installation.

WARNING! Installation must be performed by qualified technician. Gas leaks can cause explosion or fire.

First-Time Setup

Power on furnace; follow initial setup procedure.

  1. System check: Control panel will display diagnostic codes during startup.
  2. Set temperature: Use up/down arrows to set desired temperature.
  3. Configure operating mode: Select HEAT, FAN ONLY, or OFF as needed.
  4. Program schedule: Set daily temperature schedules if equipped with programmable thermostat.
  5. Test safety features: Verify proper operation of all safety systems.

CAUTION! Do not bypass safety systems. Ensure proper ventilation before operation.

Specifications

Controls and Settings

Access settings via digital control panel or optional thermostat.

Control Panel: POWER, MODE, TEMP UP/DOWN, FAN SPEED, RESET.

Temperature Settings: Set point adjustment, temperature display in °F or °C. Operating Modes: HEAT, FAN ONLY, OFF. Fan Settings: AUTO, CONTINUOUS, MULTI-SPEED. Advanced Settings: System diagnostics, error code display, maintenance reminders, filter change indicator.

Connecting to HVAC System

Compatible with standard forced-air duct systems.

  1. Turn off power to furnace before making connections.
  2. Connect supply duct: Secure to furnace outlet with approved fasteners.
  3. Connect return duct: Ensure proper air flow for efficient operation.
  4. Connect thermostat wires: Follow wiring diagram for proper connection.
  5. Connect humidifier (optional): If equipped with whole-house humidification.

Tip: Ensure all duct connections are airtight to maximize efficiency.

Operating Procedures

Designed for automatic operation with manual override options.

  1. Startup: Set thermostat to desired temperature above current room temperature.
  2. Normal Operation: System will cycle on/off automatically to maintain set temperature.
  3. Fan Control: Select AUTO for thermostat-controlled operation or ON for continuous circulation.
  4. Temperature Adjustment: Use thermostat or control panel to adjust temperature settings.
  5. System Shutdown: Set thermostat to OFF position or use power switch on furnace.
  6. Vacation Mode: Set to lower temperature when away for extended periods.

WARNING! Do not attempt to repair gas components. Contact qualified service technician.

Safety Features

Flame Rollout Switch: Shuts off gas if flame detected outside combustion chamber. High Limit Switch: Prevents overheating. Pressure Switch: Ensures proper venting. Ignition Lockout: Prevents repeated ignition attempts. Carbon Monoxide Detection: Monitors combustion gases.

Maintenance & Cleaning

Turn off power and gas supply before maintenance. Replace air filter every 1-3 months. Clean flame sensor annually. Inspect burners and heat exchanger yearly. Check vent system for obstructions.

CAUTION! Only qualified technicians should service gas and electrical components. Keep area around furnace clear of combustible materials.

Regulatory Information

ANSI Z21.47: Certified for gas-fired central furnaces. UL 727: Standard for commercial and industrial gas-fired furnaces. CSA International: Certified for safety and performance. For support, visit www.hydroflame.com or contact 1-800-555-HEAT. All installations must comply with local building codes.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower, thermostat, gas supplyCheck circuit breaker; verify thermostat setting; ensure gas valve is open.
No heatPilot/ignition, filterCheck for ignition; replace dirty air filter; verify gas supply.
Short cyclingFilter, thermostat locationReplace filter; check thermostat placement away from heat sources.
Blower doesn't stopFan setting, limit switchCheck fan setting (AUTO/ON); inspect high limit switch.
Unusual noisesBlower, ductwork, combustionInspect blower wheel; check duct connections; verify proper combustion.
Error codes displayedSystem faultsRefer to error code chart in manual; contact service if persistent.

Reset: Turn power off for 30 seconds, then restart.

Service: 1-800-555-HEAT; www.hydroflame.com

Hydro Flame Furnace Owners Manual © - All Rights Reserved 2025