The ICP WFMR090B042B is a high-efficiency gas furnace with 90,000 BTU input capacity, 80% AFUE rating, single-stage operation, natural gas fuel type, multi-speed blower motor, electronic ignition system, durable heat exchanger, and built-in safety controls. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Heat exchanger, blower assembly, gas valve, igniter, flame sensor, pressure switches, control board.
| Feature | Description |
|---|---|
| Heat Exchanger | Durable aluminized steel construction |
| Blower Motor | Multi-speed ECM motor for efficient airflow |
| Gas Valve | Single-stage automatic gas control |
| Ignition System | Hot surface electronic ignition |
| Flame Sensor | Safety device to detect burner flame |
| Pressure Switches | Verify proper venting operation |
| Control Board | Integrated furnace controller with diagnostic LEDs |
| Air Filter | Standard 1-inch filter slot |
| Thermostat Connections | Standard 24V thermostat terminals |
| Safety Switches | Door safety interlock system |
Unpack and inspect all components. Verify proper clearances and location requirements.
WARNING! Gas furnace installation must be performed by qualified HVAC technician. Improper installation can cause fire, explosion, or carbon monoxide poisoning.
Complete installation verification and initial startup procedure.
CAUTION! Always check for gas leaks using soap solution before initial startup.
Access control board via front panel. Integrated diagnostic LED for troubleshooting.
Control Board: POWER switch, Fuse, Thermostat terminals, Gas valve connector, Blower motor connections, Pressure switch terminals, Limit switch connections.
Operating Modes: Heating mode activated by thermostat call for heat. Blower delay settings: 30-second blower-on delay, 90-second blower-off delay. Temperature rise: Verify 35-65°F temperature rise across heat exchanger. Airflow settings: Adjust blower speeds for proper CFM delivery.
Natural gas supply connection requirements and procedures.
Tip: Always purge air from gas line before initial ignition.
Power supply and control wiring connections.
WARNING! Electrical work must comply with NEC and local codes. Use lockout/tagout procedures.
Regular maintenance schedule and procedures for optimal performance.
CAUTION! Always disconnect power and gas supply before performing maintenance.
Carbon monoxide detectors required in sleeping areas. Maintain proper clearances to combustibles.
WARNING! Never operate furnace without door panels installed. Keep combustible materials away from furnace. Install CO detectors according to manufacturer instructions.
ANSI Z21.47/CSA 2.3: Certified for natural gas operation. UL listed. Complies with U.S. Department of Energy efficiency standards. Manufactured by International Comfort Products. For technical support, contact 1-800-ICP-HELP or visit www.icpindex.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power/thermostat | Check circuit breaker; verify thermostat setting; check door switch. |
| No heat | Gas supply/ignition | Verify gas valve on; check for ignition lockout; inspect flame sensor. |
| Short cycling | Airflow/overheating | Check air filter; verify proper airflow; inspect limit switch. |
| Blower not running | Motor/control | Check blower capacitor; verify control board signals; test motor windings. |
| Lockout condition | Safety tripped | Reset power; check pressure switches; verify venting; inspect flame rollout switches. |
Diagnostic Codes: Refer to control board LED flash patterns for specific error codes.
Service: 1-800-ICP-HELP; www.icpindex.com