The ICP WFMR090B042B1 is a high-efficiency gas furnace with 90,000 BTU input capacity, multi-speed blower motor, electronic ignition system, durable heat exchanger, and advanced safety controls. Designed for residential heating applications with up to 90% AFUE rating. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Multi-speed direct drive blower, hot surface ignition, aluminized steel heat exchanger, integrated control board, pressure switches, flame sensor, and limit controls.
| Feature | Description |
|---|---|
| Input Capacity | 90,000 BTU/H |
| AFUE Rating | Up to 90% |
| Blower Motor | Multi-speed direct drive |
| Ignition System | Hot surface electronic ignition |
| Heat Exchanger | Aluminized steel tubular |
| Gas Type | Natural gas |
| Venting | PVC pipe (2-inch recommended) |
| Electrical | 115V, 60Hz |
| Dimensions | See specifications section |
| Weight | Approximately 120 lbs |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas appliances can be hazardous; installation must be performed by qualified technician. Ensure proper combustion air and ventilation.
Initial startup must be performed by qualified technician.
CAUTION! Never operate furnace without proper venting. Test for gas leaks before startup.
Integrated control board manages all furnace operations with LED status indicators.
Control Board Features: Self-diagnostic capability, status LED, blower control, gas valve control, safety lockout.
Thermostat Connections: R (24V), W (Heat), G (Fan), C (Common). Blower Speed Settings: Adjust cooling and heating speeds via motor taps. Limit Settings: Factory set high limit control (200°F). Pressure Switch: Monitors venting operation.
Proper venting is critical for safe operation. Use PVC pipe only.
Tip: Always check vent pipes for obstructions before each heating season.
Furnace operates automatically when thermostat calls for heat.
WARNING! If furnace fails to start after multiple attempts, call for service. Do not attempt repeated manual resets.
Annual maintenance by qualified technician recommended.
CAUTION! Turn off gas and electrical power before performing any maintenance.
Carbon monoxide detectors required in home with gas appliances.
DANGER! Gas leaks can cause explosion or fire. If you smell gas, evacuate immediately and call emergency services. Do not operate electrical switches or create sparks.
ANSI Z21.47: Certified for natural gas operation. UL: Listed for safety. Meets U.S. Department of Energy efficiency standards. For technical support, contact ICP at 1-877-4-ICP-PRO or visit www.icpindex.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, switch | Check circuit breaker, thermostat setting, door switch |
| No heat | Gas supply, ignition | Verify gas valve on, check for ignition attempts |
| Short cycling | Filter, limit switch | Replace air filter, check for blocked vents |
| Blower won't stop | Thermostat, control board | Check thermostat fan setting, control board operation |
| Lockout condition | Safety device tripped | Reset power, check LED status code |
Reset Procedure: Turn power off for 30 seconds, then restore.
Service: 1-877-4-ICP-PRO; www.icpindex.com