The ICP WFAR100C048B1 is a high-efficiency gas furnace with 100,000 BTU input capacity, 80% AFUE rating, multi-speed blower motor, electronic ignition system, durable heat exchanger, and built-in safety controls. Designed for residential forced-air heating systems with compatibility for central air conditioning. Below are key sections for safety, specifications, installation, operation, maintenance, and troubleshooting.
Key components: Heat exchanger, blower assembly, gas valve, electronic ignition, pressure switches, limit controls, venting system.
| Feature | Description |
|---|---|
| Heat Exchanger | Durable aluminized steel construction |
| Blower Motor | Multi-speed ECM motor for efficient airflow |
| Ignition System | Hot surface electronic ignition |
| Gas Valve | Automatic gas flow regulation |
| Pressure Switches | Safety verification of venting operation |
| Limit Controls | Over-temperature protection |
| Venting | Category I venting system |
| Filter System | Standard 1-inch filter slot |
| Thermostat Connection | Standard 24VAC control wiring |
| Power Requirements | 120V AC, 60Hz |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas appliances can be hazardous; installation must comply with all codes. Carbon monoxide hazard exists with improper installation.
Initial startup must be performed by qualified technician.
CAUTION! Never attempt first startup without proper training and equipment.
Integrated control board with LED status indicator. Access via control panel cover.
Control Board: LED status lights for diagnostic codes, dip switch settings for blower speeds and timing.
Thermostat Settings: Heat/Off/Auto, fan On/Auto, temperature setpoint. Blower Settings: Heating and cooling speeds adjustable via dip switches. Timing: Adjustable fan on/off delays. Safety: Automatic lockout with diagnostic codes.
Gas: 1/2" NPT gas connection. Electrical: 120V power and 24V thermostat connections. Vent: 4" round vent connector. Duct: Supply and return plenum connections.
Tip: Always use two wrenches when making gas connections to prevent damage.
Normal operation controlled by thermostat.
WARNING! Never operate furnace with access panels removed. Keep combustibles away from furnace.
Flame Rollout Switches: Detect improper burner operation. Limit Switches: Prevent over-temperature conditions. Pressure Switches: Verify proper venting operation. Ignition Control: Safe start-up and shutdown sequences.
Annual professional maintenance recommended. Monthly filter inspection required.
CAUTION! Turn off gas and electrical power before any maintenance. Only qualified technicians should service internal components.
ANSI Z21.47: Certified for natural gas operation. UL: Listed for safety standards. CSA: Certified for Canadian installations. All installations must comply with National Fuel Gas Code NFPA 54 and local codes. For technical support, contact ICP at 1-800-427-2983 or visit www.icpindex.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Thermostat/Power/Gas | Check thermostat setting; verify power and gas supply; check filter. |
| Furnace locks out | Safety device tripped | Check diagnostic lights; reset power; call for service if recurring. |
| Blower won't stop | Thermostat/Fan limit | Check thermostat fan setting; verify fan limit control operation. |
| Unusual noises | Mechanical issues | Check for loose components; verify blower wheel condition; call technician. |
| Pilot/ignition failure | Gas/Electrical | Verify gas supply; check igniter condition; ensure proper grounding. |
Reset: Turn power off for 30 seconds then restore.
Service: 1-800-427-2983; www.icpindex.com