The Intertherm Gas Furnace is a high-efficiency heating system designed for residential use, featuring natural gas operation, electronic ignition, variable-speed blower motor, multi-speed settings, safety shut-off controls, diagnostic LED indicators, and energy-saving operation modes. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Gas valve assembly, heat exchanger, blower motor, electronic ignition system, thermostat connection, pressure switches, flame sensor, and diagnostic LED.
| Feature | Description |
|---|---|
| Gas valve | Controls natural gas flow to burner assembly |
| Heat exchanger | Stainless steel construction for efficient heat transfer |
| Blower motor | Variable-speed ECM motor for quiet operation |
| Electronic ignition | Hot surface igniter for reliable startup |
| Thermostat connection | Compatible with standard 24V thermostats |
| Pressure switches | Safety devices monitoring venting system |
| Flame sensor | Detects burner flame for safety shutdown |
| Diagnostic LED | Flashing codes for troubleshooting |
| Filter access | Front-loading filter compartment |
| Power switch | On/off control for furnace operation |
Unpack and inspect all components. Ensure proper clearances and venting.
WARNING! Installation must be performed by qualified HVAC technician. Improper installation can cause fire, explosion, or carbon monoxide poisoning.
Complete installation verification before initial startup.
CAUTION! Never bypass safety controls. Test carbon monoxide detectors after installation.
Access control board via front panel. Integrated control module with diagnostic capabilities.
Control Board: POWER switch, STATUS LED, DIP switches, fuse, reset button.
Thermostat Settings: HEAT/COOL/OFF mode, FAN AUTO/ON, temperature setpoint. Blower Settings: Multi-speed configurations via DIP switches. Gas Valve: Pressure adjustment screw, manual shutoff. Safety Controls: Limit switches, rollout switches, pressure switches, flame sensor.
Normal heating cycle operation and seasonal startup procedures.
Tip: Allow 30 seconds between thermostat adjustments to prevent short cycling.
Regular maintenance ensures optimal performance and safety.
WARNING! Turn off gas and electrical power before performing any maintenance. Only qualified technicians should service gas components.
Multiple safety systems protect against hazardous conditions.
| Safety Feature | Function |
|---|---|
| Flame rollout switches | Detects burner flame outside combustion chamber |
| High limit switch | Shuts off burners if overheating detected |
| Pressure switches | Ensures proper venting before ignition |
| Flame sensor | Confirms burner ignition; shuts off gas if no flame |
| Gas valve | Automatic shutoff during power loss or safety lockout |
| Fuse protection | Protects control circuit from electrical overload |
Proper cleaning maintains efficiency and extends furnace life.
CAUTION! Never use water or chemical cleaners on furnace components. Keep area around furnace clear of flammable materials.
ANSI Z21.47/CSA 2.3: Certified for natural gas operation. UL listed for electrical safety. Meets DOE efficiency standards. Manufactured to comply with U.S. safety and performance requirements. For technical support, contact Intertherm customer service at 1-800-XXX-XXXX or visit www.intertherm.com. Keep this manual for future reference.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, switch | Check power switch; verify thermostat settings; reset circuit breaker. |
| No heat | Gas supply, ignition | Verify gas valve on; check pilot/igniter; review diagnostic codes. |
| Short cycling | Filter, limit switch | Replace dirty filter; check for blocked vents; verify proper airflow. |
| Blower won't stop | Thermostat, control board | Check thermostat fan setting; inspect control board relay. |
| Unusual noises | Blower, ductwork | Inspect blower wheel; check for loose panels; examine duct connections. |
| Lockout condition | Safety controls | Reset power; count LED flashes; consult diagnostic chart. |
Reset Procedure: Turn power off for 30 seconds, then restore.
Service: 1-800-XXX-XXXX; www.intertherm.com