Ipsen Vacuum Furnace Manual

The Ipsen Vacuum Furnace is a high-performance industrial furnace designed for heat treatment processes in vacuum environments. It features advanced temperature control, vacuum pumping systems, gas quenching capabilities, programmable cycles, safety interlocks, and data logging. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Systems 7. Operating Procedures 8. Safety Features 9. Maintenance & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Vacuum chamber, Heating elements, Temperature control system, Vacuum pumping system, Gas quenching system, Control panel, Safety interlocks.

FeatureDescription
Vacuum chamberStainless steel construction for high vacuum integrity
Heating elementsGraphite or molybdenum elements for high temperature operation
Temperature controlPrecise PID control up to 1300°C
Vacuum pumping systemMechanical pump and diffusion pump for high vacuum levels
Gas quenchingHigh-pressure gas cooling system
Control panelTouchscreen interface with programmable cycles
Safety interlocksMultiple safety systems for operator protection
Data loggingRecords process parameters for quality control
Water coolingIntegrated cooling system for furnace components
Power requirements3-phase electrical supply

Installation

Unpack and inspect contents. Place on level foundation.

  1. Foundation preparation: Ensure level concrete foundation capable of supporting furnace weight.
  2. Electrical connections: Connect 3-phase power supply according to local electrical codes.
  3. Water connections: Connect cooling water supply and return lines.
  4. Gas connections: Connect process gas and quench gas supplies.
  5. Vacuum system: Connect roughing pump and check oil levels.

WARNING! Furnace is heavy; use proper lifting equipment. Ensure all utilities are properly connected and rated for required specifications.

First-Time Setup

Power on furnace; follow initial setup procedure.

  1. System initialization: Power on control system and allow self-test to complete.
  2. Vacuum system check: Perform initial pump-down to verify vacuum integrity.
  3. Temperature calibration: Verify thermocouple readings and calibrate if necessary.
  4. Safety system test: Verify all safety interlocks are functioning properly.
  5. Program setup: Configure basic process programs for common heat treatments.

CAUTION! Only qualified personnel should perform initial setup. Wear appropriate PPE during all operations.

Specifications

Controls and Settings

Access control system via touchscreen interface. Main controls: POWER, VACUUM START, HEAT START, GAS QUENCH, EMERGENCY STOP.

Programming: Create and modify process recipes with temperature segments, vacuum levels, and gas flows. Safety: Door interlocks, over-temperature protection, water flow monitoring, vacuum safety.

Temperature Control: Setpoints, ramp rates, soak times. Vacuum Control: Pump sequencing, pressure setpoints. Gas Control: Process gas flows, quench gas pressure. System: Calibration, maintenance counters, user access levels.

Connecting Systems

Electrical: 3-phase power connection. Water: Cooling water supply and return. Gas: Process and quench gas connections. Vacuum: Pump connections and gauges.

  1. Ensure all utilities are turned off before making connections.
  2. Verify all connections are tight and leak-free.
  3. Check that all safety devices are properly connected and functional.
  4. Confirm utility specifications match furnace requirements.

Tip: Use thread sealant appropriate for vacuum service on all gas and vacuum connections.

Operating Procedures

Standard heat treatment cycle operation.

  1. Loading: Open door and load parts onto furnace hearth.
  2. Evacuation: Close door and start vacuum pumps to achieve base pressure.
  3. Heating: Start heating cycle according to programmed recipe.
  4. Soaking: Maintain temperature for specified time period.
  5. Cooling: Initiate cooling cycle (furnace cool or gas quench).
  6. Unloading: Vent chamber to atmosphere and remove processed parts.
  7. Shutdown: Follow proper shutdown procedure if furnace will be idle.

WARNING! Never open door when chamber is under vacuum or at high temperature. Always wear heat-resistant gloves when handling hot parts.

Safety Features

Multiple safety systems: Door interlocks prevent operation when door is open. Over-temperature protection automatically shuts off heaters. Water flow monitoring stops operation if cooling is inadequate. Vacuum safety prevents heating if vacuum is insufficient. Emergency stop buttons at multiple locations.

Maintenance & Cleaning

Regular maintenance schedule: Daily visual inspections. Weekly vacuum pump oil checks. Monthly chamber cleaning. Quarterly safety system verification. Annual comprehensive maintenance.

CAUTION! Always disconnect power before performing maintenance. Allow furnace to cool completely before cleaning. Use only approved cleaning materials.

Regulatory Information

CE certified: Complies with European machinery directive. UL listed: Meets North American safety standards. ISO 9001: Manufactured under quality management system. Copyright © Ipsen International GmbH. All rights reserved. For technical support, contact Ipsen service department or authorized service provider.

Troubleshooting

SymptomPossible CauseCorrective Action
Poor vacuumLeaks or pump issuesCheck for leaks; verify pump operation; change pump oil if contaminated.
Heaters not workingPower or element failureCheck power supply; inspect heating elements for damage; verify connections.
Temperature inaccurateThermocouple issuesVerify thermocouple connections; calibrate or replace thermocouple.
Water flow alarmRestricted flowCheck water supply pressure; clean filters; verify pump operation.
Door won't closeInterlock or mechanical issueCheck interlock switches; inspect door mechanism; clear obstructions.

Reset: Control system > Maintenance > Reset alarms after addressing root cause.

Service: Contact Ipsen technical support or authorized service provider for major repairs.

Ipsen Vacuum Furnace Manual © - All Rights Reserved 2025