The Janitrol Furnace 3061 4 is a high-efficiency gas furnace designed for residential heating applications. This model features a durable steel heat exchanger, electronic ignition system, variable-speed blower motor, and multiple safety controls. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Steel heat exchanger, electronic ignition, variable-speed blower, gas valve, limit switches, pressure switches, and control board.
| Feature | Description |
|---|---|
| Heat Exchanger | Durable steel construction for efficient heat transfer |
| Ignition System | Electronic hot surface ignition for reliable startup |
| Blower Motor | Variable-speed ECM motor for quiet operation |
| Gas Valve | Precision gas control with multiple safety features |
| Limit Switches | Prevents overheating by shutting off burners |
| Pressure Switches | Ensures proper venting before ignition |
| Control Board | Microprocessor-based for system monitoring |
| Filter Rack | Standard 1-inch filter size for easy maintenance |
| Flue Outlet | 3-inch PVC vent connection |
| Gas Connection | 1/2-inch NPT gas line connection |
Unpack and inspect all components. Ensure proper clearances and venting requirements.
WARNING! Installation must be performed by qualified HVAC technician. Gas connections require leak testing.
After installation, perform initial startup and system check.
CAUTION! Never bypass safety controls. Always follow proper startup procedures.
Access control board via front panel. Thermostat controls heating cycles and fan operation.
Control Board LEDs: Green (power), Yellow (heating), Red (error/fault).
Temperature Settings: Adjust via thermostat (heat setpoint, fan auto/on). Blower Settings: Adjust dip switches on control board for CFM and delay timers. Gas Pressure: Factory set, adjustable by qualified technician only. Limit Controls: Auto-reset high limit switch for overheating protection.
Proper integration with existing HVAC components is essential for optimal performance.
Tip: Ensure proper airflow by calculating duct static pressure.
Normal operation is controlled through the thermostat.
WARNING! Never operate without proper venting and air filters installed.
Multiple safety systems protect against hazardous conditions: Flame rollout switch, high limit switch, pressure switches, igniter safety timeout, gas valve safety shutoff.
Regular maintenance ensures optimal performance and longevity.
CAUTION! Always disconnect power before performing any maintenance. Gas components should only be serviced by qualified technicians.
UL listed and ANSI Z21.47 compliant. Meets DOE energy efficiency standards. Manufactured to comply with all applicable safety codes and standards. For technical support, contact Janitrol Customer Service at 1-800-654-3286 or visit www.janitrol.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Thermostat setting, power, gas supply | Check thermostat setting, circuit breaker, gas valve position |
| Furnace won't start | Limit switch, pressure switch, igniter | Reset limit switch, check venting, inspect igniter |
| Short cycling | Dirty filter, restricted airflow | Replace filter, check ductwork for restrictions |
| Blower won't stop | Thermostat fan setting, control board | Check thermostat fan setting (AUTO/ON), inspect control board |
| Unusual noises | Loose components, airflow issues | Tighten access panels, check blower wheel balance |
| Error code flashing | System fault detected | Count LED flashes and refer to fault code chart |
Reset: Power cycle furnace by turning off power for 30 seconds then restoring.
Service: 1-800-654-3286; www.janitrol.com