The Keeprite G9MVE is a high-efficiency gas furnace featuring variable-speed ECM motor technology, multi-stage heating capability, durable aluminized steel heat exchanger, electronic ignition system, built-in diagnostic controls, pressure switch safety, condensate drain system, and compatibility with standard thermostat wiring. Rated for residential use with AFUE ratings up to 96%. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Variable-speed ECM blower motor, aluminized steel primary heat exchanger, stainless steel secondary heat exchanger, hot surface ignitor, pressure switches, flame sensor, control board, condensate drain system.
| Feature | Description |
|---|---|
| Variable-speed ECM motor | Energy-efficient blower operation with precise airflow control |
| Multi-stage heating | Two-stage gas valve for efficient temperature control |
| Aluminized steel heat exchanger | Durable primary heat exchanger for long service life |
| Stainless steel secondary | Corrosion-resistant secondary heat exchanger |
| Hot surface ignition | Electronic ignition system for reliable starts |
| Diagnostic LED | Built-in status light for troubleshooting |
| Pressure switches | Safety switches for proper venting operation |
| Condensate drain | PVC piping for condensate removal |
| Gas valve | Two-stage natural gas control |
| Flame sensor | Safety device to detect burner flame |
Unpack and inspect contents. Ensure proper location with adequate clearance.
WARNING! Gas appliances require professional installation. Follow all local codes. Ensure proper ventilation.
Power on furnace; follow startup sequence.
CAUTION! Never bypass safety devices. Ensure proper combustion air supply.
Access control board via front panel. LED status light indicates system operation.
Control Board: Integrated furnace controller with diagnostic capabilities.
Heating Stages: Low fire and high fire operation based on heating demand. Blower Control: Variable-speed operation with adjustable airflow. Safety Features: Pressure switches, flame rollout switches, high-limit switches. Diagnostic Codes: LED flash patterns indicate specific error conditions. Dip Switches: Configurable settings for blower speed, timing delays.
Standard thermostat connections: R (power), W (heat), G (fan), C (common), Y (cooling).
Tip: Use compatible two-stage heating thermostat for full functionality.
Supports heating and continuous fan operation.
WARNING! Never operate furnace with access panels removed. Keep combustible materials away.
Annual professional inspection recommended. Monthly filter changes during heating season.
Turn off power before servicing. Replace air filters regularly. Keep area around furnace clean.
CAUTION! Only qualified technicians should service gas components. Never use compressed air to clean heat exchanger.
ANSI Z21.47: Certified for natural gas operation. CSA International approved. UL listed components. For support, visit www.keeprite.com or contact 1-800-465-4656. Manufactured to meet or exceed industry standards for safety and performance.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power/thermostat | Check circuit breaker; verify thermostat settings; ensure gas valve open. |
| No heat | Ignition/safety | Check LED error code; verify flame sensor; inspect pressure switches. |
| Short cycling | Filter/airflow | Replace dirty filter; check for blocked vents; verify proper airflow. |
| Blower not running | Motor/control | Check blower door switch; verify motor operation; inspect control board. |
| Error codes flashing | System fault | Count LED flashes; refer to diagnostic chart in manual. |
Reset: Turn power off for 30 seconds, then restore.
Service: 1-800-465-4656; www.keeprite.com