Lennox 0F5 119M Oil Furnace Manual

The Lennox 0F5 119M is a high-efficiency oil furnace designed for residential heating applications. This unit features advanced combustion technology, durable construction, and reliable performance for consistent home heating. Below are key sections covering safety, installation, operation, maintenance, and troubleshooting.

1. Safety Precautions 2. Installation Guidelines 3. Technical Specifications 4. Operating Instructions 5. Maintenance Procedures 6. Control System Overview 7. Venting Requirements 8. Fuel System Components 9. Electrical Connections 10. Troubleshooting Guide

Safety Precautions

Critical safety information for proper installation and operation.

HazardPrecaution
Fire/ExplosionKeep combustible materials away from furnace
Carbon MonoxideEnsure proper venting and annual inspection
Electrical ShockDisconnect power before servicing
BurnsAllow furnace to cool before maintenance
Fuel LeaksInspect oil lines regularly for damage

Installation Guidelines

Proper installation procedures for optimal performance.

  1. Location: Install in dry, well-ventilated area with adequate clearance.
  2. Foundation: Place on solid, level surface capable of supporting unit weight.
  3. Venting: Follow local codes for chimney or vent pipe installation.
  4. Oil Supply: Install proper oil line with filter and shut-off valve.
  5. Electrical: Connect to dedicated circuit with proper grounding.

WARNING! Installation must be performed by qualified technician only.

Technical Specifications

Operating Instructions

Daily operation and seasonal startup procedures.

  1. Thermostat Setting: Set to desired temperature (minimum 68°F recommended).
  2. Power On: Ensure main power switch is in ON position.
  3. System Check: Listen for proper ignition sequence.
  4. Emergency Shutoff: Use red emergency switch if abnormal operation occurs.
  5. Seasonal Startup: Professional service recommended before heating season.

CAUTION! Never attempt to repair while unit is operating.

Maintenance Procedures

Regular maintenance schedule for optimal performance.

Maintenance TaskFrequency
Replace oil filterAnnually
Clean combustion chamberAnnually
Inspect heat exchangerAnnually
Check nozzle and electrodesAnnually
Lubricate motor bearingsAs needed

Control System Overview

Primary control components and their functions.

Venting Requirements

Proper venting specifications for safe operation.

  1. Chimney: Minimum 6" diameter, properly lined and insulated
  2. Vent Pipe: Type L vent pipe, secured with screws
  3. Clearance: Maintain 1" clearance to combustible materials
  4. Draft: 0.02 to 0.06 inches water column
  5. Barometric Damper: Properly adjusted for stable draft

Fuel System Components

Oil delivery system components and maintenance.

Electrical Connections

Wiring diagram and electrical specifications.

  1. Power Supply: 115V, 60Hz, 15 amp dedicated circuit
  2. Grounding: Proper equipment grounding required
  3. Low Voltage: 24V thermostat circuit, polarity sensitive
  4. Motor: PSC type, thermally protected
  5. Safety Circuits: Series connected for proper shutdown

Troubleshooting Guide

SymptomPossible CauseCorrective Action
No ignitionNo fuel, faulty ignitionCheck oil supply, inspect electrodes
Short cyclingDirty filter, poor draftReplace filter, check venting
Smoke/odorImproper combustionAdjust air shutter, clean chamber
LockoutSafety circuit openReset control, check cad cell
No heatThermostat, power issueCheck thermostat setting, circuit breaker