The Lennox Elite Series Furnace is a high-efficiency gas furnace designed for residential heating applications. This service manual covers installation, operation, maintenance, and troubleshooting procedures for certified HVAC technicians. The Elite Series features advanced diagnostics, variable-speed blower technology, and compatibility with Lennox iComfort thermostats for optimal performance and energy efficiency.
Critical safety information for proper furnace installation and service.
| Hazard | Precaution |
|---|---|
| Gas Leaks | Check all connections with leak detection solution before startup |
| Electrical Shock | Disconnect power before servicing electrical components |
| Carbon Monoxide | Ensure proper venting and combustion air supply |
| High Temperatures | Allow furnace to cool before handling heat exchanger |
| Moving Parts | Keep hands clear of blower wheel during operation |
Proper installation ensures optimal performance and safety.
WARNING! Installation must comply with all local codes and regulations. Only qualified technicians should install this equipment.
Wiring requirements and connection procedures.
CAUTION! Reverse polarity will damage control board. Verify hot and neutral connections.
Gas line sizing and pressure verification.
| Pipe Size | Maximum Length | BTU/H Capacity |
|---|---|---|
| 1/2" | 30 feet | Up to 80,000 BTU/H |
| 3/4" | 50 feet | Up to 120,000 BTU/H |
| 1" | 100 feet | Up to 200,000 BTU/H |
Verify manifold pressure: Natural Gas 3.5" WC ± 0.3", LP Gas 10" WC ± 0.5"
PVC vent pipe installation guidelines.
IMPORTANT: Do not reduce vent pipe size. Maintain proper clearances from windows and doors.
Step-by-step furnace commissioning process.
Normal operation and user controls.
Thermostat Settings: Compatible with Lennox iComfort thermostats for optimal efficiency
Blower Operation: Variable speed motor adjusts airflow based on heating demand
Ignition Sequence: Hot surface igniter with flame sensor safety
LED Status Light: Blinks normal operation code (1 flash every 3 seconds)
Recommended maintenance intervals for optimal performance.
| Maintenance Task | Frequency |
|---|---|
| Replace air filter | Every 1-3 months |
| Inspect heat exchanger | Annually |
| Clean blower assembly | Annually |
| Check vent system | Annually |
| Verify gas pressure | Annually |
| Lubricate induced draft motor | As needed |
LED flash codes for troubleshooting.
| Flash Code | Description | Action |
|---|---|---|
| 1 Flash | Normal operation | No action required |
| 2 Flashes | Pressure switch error | Check venting and inducer |
| 3 Flashes | Ignition failure | Check gas supply and igniter |
| 4 Flashes | Flame sense error | Clean flame sensor |
| 5 Flashes | High limit switch | Check airflow and filter |
| 6 Flashes | Rollout switch | Check heat exchanger |
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power loss, thermostat issue | Check circuit breaker, thermostat settings |
| No heat | Gas valve closed, igniter failure | Verify gas supply, check igniter continuity |
| Short cycling | Dirty filter, high limit trip | Replace filter, check airflow |
| Blower won't run | Motor failure, capacitor issue | Test motor windings, check capacitor |
| Unusual noises | Loose components, bearing wear | Tighten mounting hardware, inspect bearings |