The Lennox 80MGF is a high-efficiency gas furnace with 80% AFUE rating, featuring single-stage operation, durable heat exchanger, multi-speed blower motor, electronic ignition system, built-in diagnostic controls, safety shut-off features, and compatibility with various thermostat systems. Designed for residential heating applications with natural gas or propane capability. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Durable aluminized steel heat exchanger, induced draft combustion system, hot surface igniter, multi-speed direct drive blower, integrated control board, pressure switches, flame sensor, and filter compartment.
| Feature | Description |
|---|---|
| Heat Exchanger | Aluminized steel construction for durability and efficiency |
| Blower Motor | Multi-speed direct drive for optimal airflow |
| Ignition System | Hot surface igniter for reliable lighting |
| Control Board | Integrated diagnostic and safety controls |
| Draft Inducer | Ensures proper venting and combustion |
| Pressure Switches | Safety monitoring of combustion airflow |
| Flame Sensor | Monitors burner operation |
| Gas Valve | Regulates gas flow to burners |
| Filter Rack | Standard 1-inch filter accommodation |
| Electrical Connections | 120V AC power and thermostat terminals |
Unpack and inspect all components. Ensure proper clearances and venting requirements.
WARNING! Gas appliances can be dangerous; only qualified technicians should perform installation. Ensure proper ventilation and gas line integrity.
Complete installation checks before initial startup.
CAUTION! Never operate without proper venting. Ensure combustion air supply is adequate.
Integrated control board manages all furnace operations with LED status indicators.
Control Board Features: Self-diagnostic capability, status LED, safety lockout, automatic reset, blower control, gas valve control.
Thermostat Connections: R (24V power), W (Heat), G (Fan), C (Common). Status LED Codes: Steady green (normal operation), flashing codes indicate specific faults. Blower Speeds: Adjustable for heating and continuous fan operation via dip switches.
Compatible with most 24V thermostat systems. Basic 4-wire connection recommended.
Tip: Use thermostat with appropriate heating system compatibility. Programmable thermostats recommended for energy savings.
Normal operation controlled through thermostat settings.
WARNING! Never adjust gas pressure or limit settings without proper training and equipment.
Regular maintenance ensures optimal performance and safety.
| Frequency | Maintenance Task |
|---|---|
| Monthly | Check and replace air filter if dirty |
| Annually | Professional inspection and cleaning |
| Annually | Check heat exchanger for cracks |
| Annually | Clean burners and flame sensor |
| Annually | Check gas pressure and connections |
| Annually | Inspect vent system and drains |
| Annually | Verify safety controls operation |
Turn off power and gas supply before any cleaning. Use soft brush and vacuum for dust removal.
CAUTION! Never use water or liquid cleaners on electrical components. Keep combustion area clear of debris.
ANSI Z21.47/CSA 2.3: Certified for safety standards. UL listed. Must be installed in accordance with National Fuel Gas Code and local building codes. For natural gas installations, minimum gas supply pressure 5" w.c., maximum 14" w.c. Copyright © Lennox Industries Inc. For technical support, contact 1-800-9-LENNOX or visit www.lennox.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power off/thermostat | Check circuit breaker; verify thermostat settings and batteries. |
| No heat | Gas supply/ignition | Check gas valve; verify pilot/igniter operation; check filter. |
| Short cycling | Dirty filter/overheat | Replace air filter; check for blocked vents or registers. |
| Blower won't stop | Thermostat setting | Check thermostat fan setting (AUTO/ON); verify control board. |
| Unusual noises | Mechanical issues | Check for loose components; blower wheel balance; motor bearings. |
| Lockout condition | Safety shutdown | Check status LED code; reset power; check flame sensor. |
Reset Procedure: Turn off power for 30 seconds, then restore. Check status LED for error codes.
Service: 1-800-9-LENNOX; www.lennox.com