The Lennox G8Q3 is a high-efficiency gas furnace featuring multi-speed blower operation, electronic ignition, and advanced safety controls. This upflow furnace is designed for residential heating applications with AFUE ratings up to 80%, suitable for various climate conditions. Below are essential sections covering safety, installation, operation, maintenance, and troubleshooting procedures.
Key components: Gas valve, heat exchanger, blower assembly, electronic ignition system, pressure switches, limit controls, and diagnostic LED.
| Feature | Description |
|---|---|
| Heat Exchanger | Durable aluminized steel construction |
| Blower Motor | Multi-speed PSC motor for airflow control |
| Ignition System | Direct spark electronic ignition |
| Gas Valve | Automatic gas control with safety shutoff |
| Pressure Switches | Verify proper venting operation |
| Limit Controls | Prevent overheating conditions |
| Diagnostic LED | Flash codes for troubleshooting |
| Filter Rack | Standard 1-inch filter accommodation |
| Flue Outlet | 3-inch diameter for vent connection |
| Electrical Connection | 120V AC, 60Hz power requirement |
Unpack and inspect all components. Ensure proper clearances and level mounting surface.
WARNING! Gas appliances require professional installation. Follow all local codes and manufacturer specifications.
Complete installation verification before initial operation.
CAUTION! Never bypass safety controls. Only qualified technicians should perform startup procedures.
Access control board via front panel. Diagnostic LED provides status codes.
Thermostat: HEAT/COOL/OFF selector, temperature setting, fan AUTO/ON control.
Gas Valve: Manual shutoff, pressure regulation. Blower Control: Speed taps for airflow adjustment. Limit Switches: Automatic high-temperature cutoff. Pressure Switches: Verify inducer operation. Ignition Control: Direct spark sequencing with trial for ignition.
Category I venting; follow local codes for materials and clearances.
Tip: Always verify draft after installation and annually during maintenance.
Normal heating cycle operation and user controls.
WARNING! Never operate without filter. Keep combustion air openings clear.
Regular maintenance ensures efficient and safe operation.
CAUTION! Disconnect power before servicing. Only qualified technicians should perform internal maintenance.
Multiple safety systems protect against hazardous conditions.
| Safety Device | Function |
|---|---|
| Flame Rollout Switch | Detects flame outside combustion chamber |
| High Limit Switch | Prevents overheating conditions |
| Pressure Switches | Verify proper venting operation |
| Flame Sensor | Confirms burner ignition |
| Gas Valve | Automatic shutoff during malfunctions |
ANSI Z21.47/CSA 2.3: Certified for natural gas operation. UL listed. Must be installed in accordance with National Fuel Gas Code (NFPA 54) and local building codes. For technical support, contact Lennox Industries at 1-800-9-LENNOX or visit www.lennox.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Thermostat, power, gas supply | Check thermostat setting; verify power; ensure gas valve open. |
| Furnace locks out | Safety device tripped | Check diagnostic LED; reset power; inspect safety controls. |
| Blower doesn't run | Motor, capacitor, control | Check voltage to motor; test capacitor; verify control signal. |
| Ignition failure | Gas, igniter, sensor | Verify gas pressure; check igniter operation; clean flame sensor. |
| Short cycling | Filter, limit switch, airflow | Replace filter; check limit switch; verify proper airflow. |
Reset Procedure: Turn thermostat off, disconnect power for 30 seconds, restore power.
Service: 1-800-9-LENNOX; www.lennox.com