The Lennox Merit Series Furnace is a high-efficiency gas furnace designed for residential heating applications. Featuring durable construction, reliable performance, and energy-efficient operation, this furnace series includes models with AFUE ratings up to 80%. Below are key sections covering safety, installation, operation, maintenance, troubleshooting, and technical specifications.
Key components: Durable heat exchanger, electronic ignition system, multi-speed blower motor, integrated control board, pressure switches, flame sensor, and limit switches.
| Feature | Description |
|---|---|
| Heat Exchanger | Durable steel construction for long service life |
| Ignition System | Hot surface ignition for reliable startup |
| Blower Motor | Multi-speed ECM motor for efficient airflow |
| Control Board | Integrated microprocessor for system control |
| Pressure Switches | Safety verification of venting operation |
| Flame Sensor | Monitors burner operation for safety |
| Limit Switches | Prevents overheating by monitoring temperatures |
| Gas Valve | Precise gas flow regulation |
| Filter Rack | Standard 1-inch filter accommodation |
| Drain Connection | Condensate removal for high-efficiency models |
Professional installation required. Verify local codes and obtain necessary permits.
WARNING! Gas furnaces produce carbon monoxide; improper installation can be fatal. Installation must comply with all local codes and manufacturer specifications.
Initial startup must be performed by qualified technician.
CAUTION! Never operate furnace without proper venting and combustion air. Carbon monoxide poisoning hazard.
Integrated control board manages all furnace operations with LED status indicators.
Thermostat Operation: Set desired temperature; furnace cycles automatically. Use fan ON for continuous circulation.
Control Board LED: Flashing patterns indicate system status and error codes.
Sequence of Operation: Thermostat call for heat → inducer motor starts → pressure switch verification → hot surface ignition → gas valve opens → flame verification → blower starts after delay.
Safety Controls: Limit switches, pressure switches, flame rollout switches, and flame sensor ensure safe operation.
Proper venting is critical for safe operation and efficiency.
Tip: Regularly inspect vent pipes for obstructions or damage.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always turn off electrical power and gas supply before performing any maintenance.
Multiple safety systems protect against hazardous conditions.
Flame Rollout Switches: Detect improper burner combustion. Pressure Switches: Verify proper venting operation. Limit Switches: Prevent overheating. Flame Sensor: Confirms burner ignition. Carbon Monoxide Detection: Install CO detectors near sleeping areas.
Keep furnace area clean and unobstructed.
Cleaning: Vacuum burner area and blower compartment annually. Clean flame sensor with emery cloth. Wipe exterior surfaces with damp cloth.
Filter Replacement: Replace 1-inch filters monthly during heating season. Use proper filter size and type.
CAUTION! Never use compressed air to clean internal components. Avoid water or chemical cleaners.
ANSI Z21.47/CSA 2.3: Certified for safety standards. UL Listed: Electrical component certification. National Fuel Gas Code: Complies with NFPA 54 requirements. Local codes: Installation must meet all applicable local regulations. For technical support, contact Lennox Industries at 1-800-9-LENNOX or visit www.lennox.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat settings, door switch engagement. |
| No heat | Gas supply, igniter, flame sensor | Verify gas valve on, check igniter operation, clean flame sensor. |
| Short cycling | Filter, limit switch, airflow | Replace dirty filter, check for restricted airflow, verify limit switch. |
| Blower won't stop | Thermostat fan setting | Check thermostat fan setting (ON vs AUTO). |
| Unusual noises | Blower, inducer, ductwork | Inspect blower wheel, inducer motor, check for loose components. |
| Error code flashing | Control board diagnostics | Count LED flashes and refer to error code chart in manual. |
Reset Procedure: Turn power off for 30 seconds, then restore power.
Professional Service: 1-800-9-LENNOX; www.lennox.com