Lennox Merit Series Furnace Manual

The Lennox Merit Series Furnace is a high-efficiency gas furnace designed for residential heating applications. Featuring durable construction, reliable performance, and energy-efficient operation, this furnace series includes models with AFUE ratings up to 80%. Below are key sections covering safety, installation, operation, maintenance, troubleshooting, and technical specifications.

1. Features at a Glance 2. Installation Requirements 3. First-Time Setup 4. Technical Specifications 5. Controls and Operation 6. Venting and Combustion Air 7. Maintenance Procedures 8. Safety Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Durable heat exchanger, electronic ignition system, multi-speed blower motor, integrated control board, pressure switches, flame sensor, and limit switches.

FeatureDescription
Heat ExchangerDurable steel construction for long service life
Ignition SystemHot surface ignition for reliable startup
Blower MotorMulti-speed ECM motor for efficient airflow
Control BoardIntegrated microprocessor for system control
Pressure SwitchesSafety verification of venting operation
Flame SensorMonitors burner operation for safety
Limit SwitchesPrevents overheating by monitoring temperatures
Gas ValvePrecise gas flow regulation
Filter RackStandard 1-inch filter accommodation
Drain ConnectionCondensate removal for high-efficiency models

Installation Requirements

Professional installation required. Verify local codes and obtain necessary permits.

  1. Location selection: Install in dry, clean area with adequate clearance for service access.
  2. Gas connection: Use approved black iron pipe; pressure test for leaks.
  3. Electrical connection: 120V AC power supply with proper grounding.
  4. Venting system: Category I venting for non-condensing models; PVC for condensing models.
  5. Combustion air: Ensure adequate fresh air supply per local codes.

WARNING! Gas furnaces produce carbon monoxide; improper installation can be fatal. Installation must comply with all local codes and manufacturer specifications.

First-Time Setup

Initial startup must be performed by qualified technician.

  1. Verify installation: Check all connections, clearances, and venting.
  2. Electrical power: Turn on furnace disconnect and verify control board power.
  3. Gas supply: Open main gas valve and verify proper pressure.
  4. Thermostat connection: Connect and configure compatible thermostat.
  5. Test operation: Initiate heating cycle and verify proper sequence.
  6. Airflow adjustment: Set blower speed for proper temperature rise.
  7. Combustion analysis: Verify proper gas pressure and combustion readings.

CAUTION! Never operate furnace without proper venting and combustion air. Carbon monoxide poisoning hazard.

Technical Specifications

Controls and Operation

Integrated control board manages all furnace operations with LED status indicators.

Thermostat Operation: Set desired temperature; furnace cycles automatically. Use fan ON for continuous circulation.

Control Board LED: Flashing patterns indicate system status and error codes.

Sequence of Operation: Thermostat call for heat → inducer motor starts → pressure switch verification → hot surface ignition → gas valve opens → flame verification → blower starts after delay.

Safety Controls: Limit switches, pressure switches, flame rollout switches, and flame sensor ensure safe operation.

Venting and Combustion Air

Proper venting is critical for safe operation and efficiency.

  1. Vent pipe sizing: Follow manufacturer specifications for pipe diameter and length.
  2. Vent termination: Locate away from windows, doors, and air intakes.
  3. Combustion air: Provide adequate fresh air per installation requirements.
  4. Condensate drainage: For high-efficiency models, ensure proper condensate trap and drainage.

Tip: Regularly inspect vent pipes for obstructions or damage.

Maintenance Procedures

Regular maintenance ensures optimal performance and longevity.

  1. Monthly: Check and replace air filter as needed.
  2. Annual professional service: Includes combustion analysis, heat exchanger inspection, blower cleaning, and safety check.
  3. Seasonal: Inspect vent system, check drain lines, verify thermostat operation.
  4. Component inspection: Check burners, flame sensor, igniter, and safety controls.

WARNING! Always turn off electrical power and gas supply before performing any maintenance.

Safety Features

Multiple safety systems protect against hazardous conditions.

Flame Rollout Switches: Detect improper burner combustion. Pressure Switches: Verify proper venting operation. Limit Switches: Prevent overheating. Flame Sensor: Confirms burner ignition. Carbon Monoxide Detection: Install CO detectors near sleeping areas.

Care & Cleaning

Keep furnace area clean and unobstructed.

Cleaning: Vacuum burner area and blower compartment annually. Clean flame sensor with emery cloth. Wipe exterior surfaces with damp cloth.

Filter Replacement: Replace 1-inch filters monthly during heating season. Use proper filter size and type.

CAUTION! Never use compressed air to clean internal components. Avoid water or chemical cleaners.

Regulatory Information

ANSI Z21.47/CSA 2.3: Certified for safety standards. UL Listed: Electrical component certification. National Fuel Gas Code: Complies with NFPA 54 requirements. Local codes: Installation must meet all applicable local regulations. For technical support, contact Lennox Industries at 1-800-9-LENNOX or visit www.lennox.com.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower, thermostat, door switchCheck circuit breaker, thermostat settings, door switch engagement.
No heatGas supply, igniter, flame sensorVerify gas valve on, check igniter operation, clean flame sensor.
Short cyclingFilter, limit switch, airflowReplace dirty filter, check for restricted airflow, verify limit switch.
Blower won't stopThermostat fan settingCheck thermostat fan setting (ON vs AUTO).
Unusual noisesBlower, inducer, ductworkInspect blower wheel, inducer motor, check for loose components.
Error code flashingControl board diagnosticsCount LED flashes and refer to error code chart in manual.

Reset Procedure: Turn power off for 30 seconds, then restore power.

Professional Service: 1-800-9-LENNOX; www.lennox.com