The Lindberg/Blue MiniMite Tube Furnace is a compact, high-temperature laboratory furnace designed for research and industrial applications. It features precise temperature control, rapid heating capabilities, and a durable ceramic fiber insulation system. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Ceramic heating elements, digital temperature controller, quartz tube chamber, thermal safety cutouts, and cooling fan.
| Feature | Description |
|---|---|
| Heating Elements | High-temperature ceramic elements for uniform heating |
| Temperature Controller | Digital PID controller with programmable profiles |
| Tube Chamber | Quartz tube for high-temperature applications |
| Safety Cutouts | Over-temperature protection |
| Cooling System | Integrated fan for rapid cooling |
| Power Input | Standard 120V/240V AC operation |
| Temperature Range | Up to 1100°C maximum operating temperature |
| Heating Rate | Programmable ramp rates up to 20°C/min |
| Display | LED digital display of setpoint and actual temperature |
| Communication | RS-232 interface for data logging |
Unpack and inspect contents. Place on stable, level surface.
WARNING! Furnace operates at high temperatures; maintain safe clearance from combustible materials. Wear appropriate PPE during installation.
Power on furnace; initialize temperature controller.
CAUTION! Always perform initial setup at room temperature. Do not touch hot surfaces.
Access control functions via front panel interface. Main Controls: POWER, TEMPERATURE SET, RAMP RATE, HOLD TIME.
Controller Functions: POWER ON/OFF, Temperature display, Setpoint adjustment, Program storage, Alarm settings.
Temperature Control: SETPOINT, RAMP RATE, SOAK TIME, PROGRAM MODE. Safety: OVER-TEMP PROTECTION, DOOR INTERLOCK, COOLING FAN CONTROL. System: CALIBRATION, COMMUNICATION SETUP, DISPLAY SETTINGS.
Standard operation for heating processes.
Tip: Always use thermal gloves when handling hot tubes or samples.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always disconnect power before performing maintenance. Allow furnace to cool completely.
Over-temperature protection: Automatic shutdown if temperature exceeds setpoint. Door interlock: Prevents operation when chamber access is open. Ground fault protection: Electrical safety circuit. Cooling fan: Prevents overheating of external surfaces.
Disconnect power before cleaning. Use soft, dry cloth for exterior surfaces. For stubborn stains, use mild detergent solution. Never use abrasive cleaners or solvents.
CAUTION! Do not immerse any part of furnace in liquid. Keep control panel dry at all times.
UL Listed: Complies with UL safety standards. CE Certified: Meets European Union requirements. FCC Part 15: Class A digital device. Copyright © 2025 Lindberg/Blue; trademarks of SPX Corporation. For technical support, visit www.lindbergblue.com or contact 1-800-873-2020.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't heat | Power supply/elements | Check power connection; verify heating elements; check fuses. |
| Temperature inaccurate | Calibration/thermocouple | Recalibrate controller; check thermocouple connection. |
| Over-temperature alarm | Controller settings | Check setpoint; verify over-temp protection settings. |
| Tube cracking | Thermal shock | Use proper heating/cooling rates; inspect for damage. |
| Controller display blank | Power/display | Check power supply; verify display connections. |
Reset: Power cycle controller; perform factory reset if needed.
Service: 1-800-873-2020; www.lindbergblue.com