The Luxaire GM9SO80C16UP11K is an 80,000 BTU high-efficiency gas furnace with 96% AFUE rating, two-stage heating operation, variable-speed blower motor, durable aluminized steel heat exchanger, direct spark ignition, pressure switch safety controls, multi-speed ECM motor, and compatibility with 2-inch PVC venting. Designed for residential forced-air heating systems with standard 120V AC power requirement. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Two-stage gas valve, variable-speed blower, aluminized steel primary heat exchanger, stainless steel secondary heat exchanger, direct spark ignition, pressure switches, flame sensor, inducer motor assembly.
| Feature | Description |
|---|---|
| Heating Capacity | 80,000 BTU/h input |
| AFUE Rating | 96% efficiency |
| Stages | Two-stage heating operation |
| Blower Motor | Variable-speed ECM |
| Heat Exchanger | Aluminized steel primary, stainless steel secondary |
| Ignition System | Direct spark ignition |
| Venting | 2-inch PVC compatible |
| Gas Type | Natural gas |
| Electrical | 120V AC, 60Hz |
| Control Board | Integrated furnace control with LED status lights |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas appliances can be hazardous; installation must comply with all local codes and manufacturer specifications. Carbon monoxide hazard exists with improper installation.
Professional startup and commissioning required.
CAUTION! Only qualified HVAC technicians should perform startup procedures.
Integrated furnace control board with LED status indicator. Two-stage operation for enhanced comfort and efficiency.
Control Board LED Codes: Steady green = normal operation; Slow flash = pressure switch error; Rapid flash = ignition failure; Off = no power.
Operation: Furnace communicates with thermostat for staging control. Low stage operates for mild weather, high stage for extreme cold. Variable-speed blower adjusts airflow for optimal performance and comfort.
Compatible with most two-stage heating thermostats.
Tip: Use programmable thermostat for maximum energy savings.
Annual professional maintenance recommended.
WARNING! Turn off gas and electrical power before servicing.
Multiple safety systems: Flame rollout switches, pressure switches, high-limit switches, flame sensor, igniter control.
Pressure switches: Verify proper venting before ignition. Flame rollout switches: Detect improper burner combustion. High-limit switches: Prevent overheating. Flame sensor: Confirms burner ignition. Ignition control: Safe start-up sequence.
Regular maintenance ensures optimal performance and safety.
Monthly: Replace air filter. Annual: Professional cleaning of burners, heat exchanger, blower assembly, and drain system. Keep area around furnace clean and unobstructed.
CAUTION! Never operate without filter. Keep combustion air openings clear.
ANSI Z21.47/CSA 2.3: Certified for natural gas operation. UL listed. Complies with U.S. Department of Energy efficiency standards. Manufactured to meet or exceed industry safety standards. For technical support, contact Luxaire at 1-855-583-8206 or visit www.luxaire.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, switch | Check circuit breaker, thermostat setting, door switch |
| No heat | Gas supply, ignition | Verify gas valve on; check for ignition attempts |
| Short cycling | Filter, limit switch | Replace dirty filter; check for restricted airflow |
| Blower won't stop | Thermostat, control | Check thermostat fan setting; control board issue |
| Error code flashing | Various safety locks | Refer to LED code chart; reset if safe to do so |
Reset: Turn power off for 30 seconds then restore.
Service: 1-855-583-8206; www.luxaire.com