The Luxaire furnace with rollout switch open code 5 indicates a safety lockout condition where the rollout limit switch has detected excessive heat or flame rollout. This safety feature prevents dangerous operation and potential fire hazards. Below are key sections for understanding, diagnosing, and resolving code 5 issues, along with safety precautions and maintenance guidelines.
Code 5 indicates the rollout limit switch has opened due to detected flame rollout or excessive heat in the burner compartment. This safety switch prevents continued operation when unsafe conditions are present.
| Component | Function |
|---|---|
| Rollout Switch | Detects flame rollout and excessive heat |
| Control Board | Monitors switch status and triggers lockout |
| Burner Assembly | Where combustion occurs |
| Heat Exchanger | Transfers heat to air stream |
| Flame Sensor | Verifies proper burner ignition |
Before attempting any diagnosis or repair, ensure proper safety measures are followed.
WARNING! Gas furnaces can be dangerous. If unsure, contact qualified HVAC technician. Never bypass safety switches.
Systematic approach to identify the root cause of code 5.
CAUTION! Always restore power and gas in proper sequence after servicing.
Access OSD via TV MENU or SETUP (DVD). Front Panel: POWER, OPEN/CLOSE, AUTO/DPMS, MUTE.
Primary Issues: Restricted airflow, cracked heat exchanger, improper gas pressure, blocked venting, faulty limit switch.
Airflow: Dirty filters, blocked registers, dirty blower wheel. Combustion: Gas valve issues, burner problems, flame sensor failure. Venting: Blocked flue, improper installation, negative pressure. Components: Failed rollout switch, control board issues, wiring problems.
Regular maintenance prevents recurrence of code 5 issues.
Tip: Mark maintenance dates on calendar for regular service intervals.
Luxaire furnace specifications relevant to code 5 diagnosis.
| Parameter | Specification |
|---|---|
| Rollout Switch Type | Manual reset thermal switch |
| Trip Temperature | Typically 200-250°F |
| Gas Pressure Range | 3.2-3.8" WC natural gas |
| Airflow Requirements | Model specific CFM ratings |
| Control Voltage | 24V AC |
Certain conditions require qualified HVAC technician intervention.
WARNING! Carbon monoxide hazards require immediate professional attention.
Luxaire furnace warranty coverage and limitations for code 5 related issues.
CAUTION! Unauthorized repairs may void warranty. Consult manufacturer guidelines.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Code 5 immediately after reset | Stuck switch or wiring short | Test switch continuity; check wiring |
| Code 5 after several minutes | Restricted airflow | Check filters and ductwork |
| Intermittent code 5 | Marginal venting | Inspect flue and combustion air |
| Code 5 with soot | Combustion issues | Check burners and gas pressure |
| Multiple safety trips | Systemic problem | Professional diagnosis required |
Emergency: 1-800-LUXAIRE; www.luxaire.com