The American Standard Furnace Model AUH2C100A9V4VAA is a high-efficiency gas furnace with 100,000 BTU input capacity, variable-speed blower motor, two-stage heating operation, and compatibility with various thermostat systems. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Two-stage gas valve, variable-speed ECM blower motor, hot surface igniter, flame sensor, pressure switches, and integrated control board.
| Feature | Description |
|---|---|
| Gas Valve | Two-stage operation for efficient heating |
| Blower Motor | Variable-speed ECM for quiet operation |
| Ignition System | Hot surface igniter for reliable startup |
| Flame Sensor | Safety feature to detect flame presence |
| Pressure Switches | Ensure proper venting operation |
| Control Board | Integrated system management |
| Filter Rack | Standard 1-inch filter compatibility |
| Drain Connection | For condensate removal |
| Gas Connection | 1/2-inch NPT gas line connection |
| Electrical Connection | 120V AC power supply |
Unpack and inspect contents. Position in approved location with proper clearances.
WARNING! Gas furnace installation must be performed by qualified technician only. Ensure proper ventilation and combustion air supply.
Power on furnace; follow startup sequence.
CAUTION! Never bypass safety controls. Ensure proper combustion and ventilation before operation.
Access control board via front panel removal. Integrated control board with status LED for diagnostics.
Thermostat: Compatible with two-stage heating thermostats; requires W1/W2 connections.
Blower Settings: Adjustable via dip switches for airflow customization. Gas Valve: Two-stage operation with pressure regulation. Safety Controls: Flame rollout switches, pressure switches, high limit switch. Diagnostic LED: Flashing codes indicate system status and error conditions.
Gas Line: 1/2-inch NPT connection. Vent System: PVC piping. Electrical: 120V AC power. Thermostat: Standard 24V connections.
Tip: Always use two wrenches when making gas connections to prevent damage to gas valve.
Normal heating cycle operation with two-stage capability.
WARNING! Never operate furnace without proper venting and combustion air. Monitor for unusual noises or odors.
Flame Rollout Switches: Detect improper burner operation. Pressure Switches: Ensure proper venting. High Limit Switch: Prevents overheating. Flame Sensor: Confirms proper ignition. Ignition Lockout: Prevents repeated ignition attempts.
Turn off power and gas supply before maintenance. Replace air filter monthly during heating season. Clean burners and heat exchanger annually. Inspect vent system for obstructions.
CAUTION! Only qualified technicians should perform internal maintenance. Never operate with blocked vents or dirty filters.
ANSI Z21.47: Certified for natural gas operation. UL Listed: Meets safety standards. For support, contact American Standard at 1-800-572-1111 or visit www.americanstandardair.com. Installation must comply with local building codes and utility requirements.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Power, thermostat, gas supply | Check circuit breaker; verify thermostat setting; ensure gas valve open. |
| Furnace locks out | Ignition failure | Check for blocked vent; verify gas pressure; inspect flame sensor. |
| Blower not running | Motor, control board | Check for proper voltage; inspect control board connections. |
| Short cycling | Dirty filter, high limit | Replace air filter; check for restricted airflow; verify limit switch operation. |
| Unusual noises | Blower, burners | Inspect blower wheel; clean burners; check for loose components. |
Reset: Power cycle furnace to reset control board lockout.
Service: 1-800-572-1111; www.americanstandardair.com