The Maratherm Gas Furnace is a high-efficiency residential heating system designed for reliable performance and energy savings. This manual covers installation, operation, maintenance, and troubleshooting for various Maratherm furnace models. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: High-efficiency heat exchanger, Electronic ignition system, Variable-speed blower motor, Multi-speed settings, Diagnostic LED lights, Safety shut-off valves.
| Feature | Description |
|---|---|
| Heat Exchanger | Stainless steel construction for maximum efficiency and durability |
| Ignition System | Electronic hot surface ignition for reliable starts |
| Blower Motor | Variable-speed ECM motor for quiet operation and energy savings |
| Gas Valve | Modulating gas valve for precise temperature control |
| Air Filter | Standard 1-inch or 4-inch media filter options |
| Vent System | PVC venting for sidewall or roof termination |
| Control Board | Microprocessor-based for advanced diagnostics |
| Safety Features | Flame rollout switch, pressure switch, limit switches |
| Thermostat Compatibility | Works with standard 24V and smart thermostats |
| Warranty | Limited lifetime heat exchanger warranty |
Unpack and inspect all components. Ensure proper clearances and venting requirements.
WARNING! Gas furnaces must be installed by qualified HVAC technicians only. Improper installation can cause fire, explosion, or carbon monoxide poisoning.
Complete installation verification and initial startup procedure.
CAUTION! Always perform combustion analysis and carbon monoxide testing after installation.
Access control board via front panel. Diagnostic lights indicate system status.
Control Board: POWER switch, Diagnostic LED, DIP switch settings, Service test mode.
Blower Settings: CFM adjustments via DIP switches, delay-on and delay-off timing. Gas Valve: Pressure adjustment screws, manifold pressure test ports. Thermostat: Heat/cool/auto modes, fan control, temperature setpoints. Safety Controls: Reset buttons for rollout and limit switches.
Compatible with standard 24V thermostats and most smart thermostats.
Tip: Use 18-gauge thermostat wire for runs under 50 feet; 16-gauge for longer runs.
Normal operation through connected thermostat.
WARNING! Never attempt to adjust gas pressure or safety controls without proper training and equipment.
Regular maintenance ensures optimal performance and safety.
Turn off power and gas supply before cleaning. Use soft brush and vacuum for dust removal.
CAUTION! Do not use water or liquid cleaners on electrical components. Keep combustion area clean and free of debris.
UL certified for safety standards. ANSI Z21.47 compliant for gas-fired central furnaces. Meets DOE energy efficiency requirements. For support, visit www.maratherm.com or contact 1-800-555-HEAT. All installations must comply with local building codes and regulations.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, safety switch | Check circuit breaker, thermostat settings, reset safety switches. |
| No heat | Gas supply, ignition | Verify gas valve on, check for spark at igniter, listen for gas valve click. |
| Short cycling | Dirty filter, airflow | Replace air filter, check for blocked vents or returns. |
| Blower won't stop | Thermostat, control board | Check thermostat fan setting, test limit switch, inspect control board. |
| Unusual noises | Motor, blower wheel | Inspect blower wheel for debris, check motor bearings, tighten components. |
Reset: Turn power off for 30 seconds then restore. Check diagnostic LED for error codes.
Service: 1-800-555-HEAT; www.maratherm.com