Maytag Furnace Manual

The Maytag Furnace is a high-efficiency heating system designed for residential use, featuring advanced combustion technology, variable-speed blower motor, electronic ignition, built-in diagnostics, multiple safety controls, and energy-saving operation modes. Compatible with standard thermostat systems and available in various BTU capacities. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Thermostat 7. Operation 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Heat exchanger, blower assembly, gas valve, igniter, flame sensor, pressure switches, control board, filter compartment.

FeatureDescription
Variable-speed blowerAdjusts airflow for optimal efficiency and comfort
Electronic ignitionReliable spark ignition system
Multi-speed operationAdapts to heating demands
Built-in diagnosticsLED status lights for troubleshooting
Safety controlsFlame rollout, limit switches, pressure sensors
Filter monitoringReminds when to replace air filter
Quiet operationSound-absorbing insulation
Energy efficientHigh AFUE rating
Durable constructionStainless steel heat exchanger
Easy maintenanceAccessible service panels

Installation

Unpack and inspect contents. Ensure proper location with adequate clearance.

  1. Position furnace: Place on level surface with proper clearances as specified.
  2. Connect gas line: Use approved gas piping and fittings; pressure test for leaks.
  3. Connect venting: Install proper vent pipes according to local codes.
  4. Electrical connections: Connect to 120V power supply and thermostat wiring.
  5. Install air filter: Place clean filter in filter compartment.

WARNING! Installation must be performed by qualified HVAC technician. Gas leaks can cause explosion or fire.

First-Time Setup

Power on furnace; follow startup sequence.

  1. Verify gas supply: Ensure gas valve is open and pressure is correct.
  2. Check electrical: Confirm power is connected and thermostat has batteries.
  3. Startup sequence: System will run self-check and begin normal operation.
  4. Test operation: Set thermostat to heat mode and verify proper function.
  5. Adjust settings: Configure blower speed and other parameters if needed.

CAUTION! Do not bypass safety controls. Ensure proper ventilation.

Specifications

Controls and Settings

Access control board via front service panel. LED status lights indicate system operation.

Control Board: POWER switch, LED diagnostic lights, DIP switches for configuration.

Operating Modes: HEAT, OFF, FAN ON. Blower Settings: Auto, Continuous. Temperature Control: Via thermostat. Diagnostic Codes: Flash patterns indicate specific issues. Configuration: Blower speeds, timing delays, accessory settings.

Connecting Thermostat

Standard 24V thermostat connection with R, W, G, C terminals.

  1. Turn off power to furnace before wiring.
  2. Connect thermostat wires to control board terminals.
  3. Match wire colors to terminal labels (R-red, W-white, G-green, C-common).
  4. Secure connections and restore power.
  5. Test thermostat operation.

Tip: Use programmable thermostat for maximum energy savings.

Operation

Normal heating cycle operation.

  1. Thermostat calls for heat: Sends signal to control board.
  2. Inducer motor starts: Creates draft for combustion.
  3. Pressure switch verification: Confirms proper draft.
  4. Ignition sequence: Hot surface igniter glows, gas valve opens.
  5. Flame detection: Flame sensor confirms ignition.
  6. Blower activation: Circulates warm air through ducts.
  7. Cycle completion: Thermostat satisfied, system shuts down.

WARNING! Never block air vents or returns. Maintain clear combustion air intake.

Maintenance

Regular maintenance ensures optimal performance and longevity.

Care & Cleaning

Turn off power before any cleaning. Use soft brush and vacuum for dust removal.

CAUTION! Do not use water or liquid cleaners. Keep electrical components dry.

Regulatory Information

UL listed and ANSI certified. Complies with ASHRAE standards. Manufactured to meet EPA efficiency requirements. For support, visit www.maytag.com or contact 1-800-688-9900. Serial number and model information located on unit rating plate.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower, thermostat, switchCheck circuit breaker, thermostat settings, power switch
No heatGas supply, filter, ignitionVerify gas valve open, replace filter, check pilot/igniter
Short cyclingFilter, thermostat, limit switchClean/replace filter, check thermostat location, reset limits
Blower not workingMotor, capacitor, controlCheck blower motor, capacitor, control board signals
Unusual noisesMotor, bearings, ductsLubricate motor, tighten components, check ductwork

Reset: Turn power off for 30 seconds then restore.

Service: 1-800-688-9900; www.maytag.com