The Miller Propane Furnace is a high-efficiency heating system designed for residential and light commercial applications. This furnace features advanced combustion technology, multiple safety controls, variable-speed blower motor, electronic ignition, and compatibility with standard thermostat systems. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Heat exchanger, burner assembly, blower motor, gas valve, control board, pressure switches, flame sensor, and venting system.
| Feature | Description |
|---|---|
| Heat Exchanger | Stainless steel primary and secondary heat exchangers |
| Blower Motor | Variable-speed ECM motor for efficient airflow |
| Gas Valve | Multi-stage gas valve with pressure regulation |
| Control Board | Microprocessor-based control with diagnostic LEDs |
| Ignition System | Hot surface ignition for reliable startup |
| Pressure Switches | Dual pressure switches for vent safety |
| Flame Sensor | Proves flame presence during operation |
| Limit Switches | High temperature safety cutoffs |
| Venting | PVC venting system for sidewall or roof termination |
| Thermostat Connection | Compatible with standard 24V thermostat systems |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas furnaces produce carbon monoxide. Proper installation and venting are critical for safety. Use qualified HVAC technician.
Initial startup must be performed by qualified technician.
CAUTION! Never operate furnace without proper venting. Test for gas leaks before operation.
Access control board via front panel. Diagnostic LEDs indicate system status.
Control Board: POWER LED (steady green), STATUS LED (flashing codes), HEAT LED (on during heating).
DIP Switch Settings: Heat staging, blower delays, accessory configuration. Gas Valve: Multi-stage operation with pressure regulation. Blower Control: Variable speed settings for different heating stages. Limit Controls: Manual reset high limit switches. Pressure Switches: Prove venting operation before gas valve opens.
PVC vent system required. Follow local codes for vent termination.
Tip: Always verify proper vent operation with manometer during startup.
Normal operation controlled by thermostat.
WARNING! Never block air intakes or exhaust vents. Maintain clearances around furnace.
Annual maintenance required for safe and efficient operation.
CAUTION! Turn off power and gas supply before performing maintenance.
Multiple safety systems protect against hazardous conditions.
| Safety Feature | Function |
|---|---|
| Flame Rollout Switches | Detect flame outside combustion chamber |
| High Limit Switches | Prevent overheating of heat exchanger |
| Pressure Switches | Verify proper venting before gas valve operation |
| Flame Sensor | Proves flame presence; shuts off gas if no flame |
| Ignition Control | Limited trial for ignition; locks out if failed |
| Gas Valve | Automatic shutoff in case of system fault |
UL listed and ANSI Z21.47 compliant. Certified for residential installation. CSA design certified. Installation must comply with National Fuel Gas Code NFPA 54 and local building codes. For technical support, contact Miller Heating & Cooling at 1-800-645-3676 or visit www.millerfurnace.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat setting, door switch engagement |
| No heat | Gas supply, igniter, flame sensor | Verify gas valve on, check igniter operation, clean flame sensor |
| Short cycling | Dirty filter, limit switch | Replace air filter, check for blocked vents, reset limit switch |
| Blower won't run | Motor, capacitor, control board | Check motor operation, test capacitor, verify control signal |
| Lockout condition | Ignition failure, pressure switch | Reset power, check gas pressure, verify venting, test pressure switches |
| Unusual noises | Blower, inducer, heat exchanger | Inspect blower wheel, check inducer motor, examine heat exchanger |
LED Error Codes: 1 flash - pressure switch, 2 flashes - limit switch, 3 flashes - flame rollout, 4 flashes - igniter failure, 5 flashes - flame sense
Service: 1-800-645-3676; www.millerfurnace.com