The Tempstar N2A342AKA200 is a high-efficiency gas furnace designed for residential heating applications. This 34,000 BTU furnace features variable-speed blower technology, electronic ignition, multi-speed operation, and advanced diagnostic controls. Below are key sections covering safety guidelines, technical specifications, installation procedures, operation instructions, maintenance requirements, and troubleshooting guidance.
Key components: Variable-speed blower motor, electronic ignition system, multi-position installation capability, LED diagnostic lights, integrated pressure switches, and sealed combustion system.
| Feature | Description |
|---|---|
| Variable-speed blower | Provides consistent airflow and quiet operation |
| Electronic ignition | Energy-efficient hot surface ignition system |
| Multi-position installation | Can be installed in upflow, downflow, or horizontal configurations |
| LED diagnostic lights | Provides error codes for troubleshooting |
| Sealed combustion | Draws outside air for combustion for improved efficiency |
| Pressure switches | Ensures proper venting before ignition |
| Gas valve | Precise gas flow control |
| Heat exchanger | Stainless steel construction for durability |
| Blower compartment | Easy access for maintenance |
| Control board | Integrated furnace controller |
Unpack and inspect all components. Ensure proper clearances and venting requirements.
WARNING! Gas furnace installation must be performed by qualified HVAC technician. Improper installation can cause fire, explosion, or carbon monoxide poisoning.
Complete installation verification before initial startup.
CAUTION! Always perform combustion analysis and verify proper operation before leaving installation.
Integrated control board with LED status lights and dip switch settings for configuration.
Control Board: Provides ignition sequence control, safety monitoring, and diagnostic capabilities.
Thermostat Connections: R (24V power), W (Heat), G (Fan), C (Common). Dip Switch Settings: Blower speeds, heating timing, accessory configuration. Diagnostic Lights: Flash codes indicate specific error conditions for troubleshooting.
Thermostat: Standard 24V connections. Venting: PVC pipe connections. Gas supply: 1/2" NPT connection.
Tip: Always pressure test gas connections before initial startup.
Normal heating operation with automatic safety monitoring.
WARNING! Never operate furnace with access panels removed or safety devices bypassed.
Flame rollout switches: Detect improper burner operation. Pressure switches: Verify proper venting. High limit switch: Prevents overheating. Flame sensor: Confirms burner ignition.
Annual maintenance required by qualified technician. Turn off power and gas before servicing.
CAUTION! Only qualified HVAC technicians should perform internal maintenance. Homeowners should only replace air filters regularly.
ANSI Z21.47: Certified for natural gas operation. UL listed. Complies with U.S. Department of Energy efficiency standards. Installation must comply with National Fuel Gas Code NFPA 54 and local building codes. For technical support, contact Tempstar at 1-877-737-7466 or visit www.tempstar.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat settings, ensure door panels secure. |
| No heat | Gas supply, ignition | Verify gas valve on, check for ignition lockout, reset if needed. |
| Blower won't stop | Thermostat, control board | Check thermostat fan setting, inspect control board operation. |
| Furnace cycles on limit | Airflow restriction | Replace air filter, check for blocked vents or registers. |
| Error code flashing | Various faults | Count LED flashes and refer to diagnostic chart in manual. |
Reset: Turn power off for 30 seconds to reset control board.
Service: 1-877-737-7466; www.tempstar.com