The Nordyne Electric Furnace is a high-efficiency heating system designed for residential and light commercial applications. This manual provides comprehensive information on parts identification, replacement procedures, technical specifications, and maintenance guidelines for Nordyne electric furnace models. Below are key sections covering parts diagrams, installation guidelines, troubleshooting, and technical specifications.
Key components: Heating elements, blower assembly, control board, sequencers, limit switches, transformer, and safety devices.
| Part Name | Description |
|---|---|
| Heating Elements | Electric resistance coils that generate heat |
| Blower Assembly | Circulates air through the duct system |
| Control Board | Main system controller and safety monitor |
| Sequencers | Controls staging of heating elements |
| Limit Switches | Safety devices that prevent overheating |
| Transformer | Steps down voltage for control circuit |
| Thermal Fuses | Over-temperature protection devices |
| Blower Motor | Drives the blower fan assembly |
| Capacitors | Provides starting torque for motors |
| Relays | Electrical switches for component control |
Proper installation ensures optimal performance and safety. Follow all local electrical codes and manufacturer specifications.
WARNING! Installation must be performed by qualified HVAC technician. Electrical shock hazard exists.
Access control board via front service panel. Main components include sequencer relays, limit controls, and transformer.
Control Board: Monitors safety circuits, controls blower operation, manages heating stages. Sequencers: Time-delay relays that stage heating elements to prevent power surge. Limit Switches: Automatic reset high-limit protection. Blower Control: Adjustable delay-on-break and delay-on-make settings.
Refer to specific model wiring diagram for proper connections. Diagrams located on inside of service panel door.
Tip: Always reference the specific model number when ordering replacement parts.
Authorized replacement parts ensure system reliability and safety.
WARNING! Always disconnect power before servicing. Use only Nordyne approved replacement parts.
Regular maintenance ensures optimal performance and extends equipment life.
High voltage electrical hazard exists. Follow all lockout/tagout procedures.
CAUTION! Electrical shock hazard. Disconnect all power sources before servicing. High temperatures present during operation.
UL listed and complies with NEC requirements. Meets ANSI Z21 standards for safety. Certified for residential installation. All components RoHS compliant. For technical support, contact Nordyne at 1-800-422-4328 or visit www.nordyne.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Power supply, sequencer, limit switch | Check circuit breakers, test sequencer operation, verify limit switch continuity. |
| Blower not running | Motor, capacitor, control board | Test motor windings, check capacitor, verify control board output. |
| Insufficient heat | Heating elements, airflow | Test element continuity, check for restricted airflow, verify voltage. |
| Frequent cycling | Dirty filter, limit switch | Replace air filter, test high limit operation, check duct restrictions. |
| Blower runs continuously | Control board, thermostat | Check thermostat settings, test control board fan relay. |
Reset: Turn power off for 30 seconds to reset control board.
Service: 1-800-422-4328; www.nordyne.com