Nordyne Furnace Manual M1MB

The Nordyne M1MB furnace is a high-efficiency gas furnace designed for residential heating applications. This multi-speed furnace features advanced combustion technology, electronic ignition, and safety controls. The M1MB series includes various models with BTU ratings from 40,000 to 120,000, suitable for different home sizes and climate conditions. Below are key sections covering safety, installation, operation, maintenance, and troubleshooting.

1. Safety Information 2. Installation Requirements 3. Technical Specifications 4. Operating Instructions 5. Control Settings 6. Venting System 7. Gas Connections 8. Electrical Wiring 9. Maintenance Procedures 10. Troubleshooting Guide 11. Warranty Information

Safety Information

Important safety precautions for installation and operation.

Warning TypeDescription
Fire/Explosion HazardKeep combustible materials away from furnace
Carbon MonoxideEnsure proper venting; install CO detectors
Electrical ShockDisconnect power before servicing
Burn HazardSurfaces become hot during operation
Gas LeaksCheck all connections with soap solution

WARNING! Installation must be performed by qualified technician only. Improper installation can cause fire, explosion, or carbon monoxide poisoning.

Installation Requirements

Proper installation guidelines and space requirements.

  1. Location: Install in clean, dry area with adequate combustion air.
  2. Clearances: Maintain 1-inch clearance from combustible materials.
  3. Venting: Follow local codes for vent pipe installation.
  4. Gas Supply: Use approved black iron pipe; install shut-off valve.
  5. Electrical: 120V AC power supply with proper grounding.

CAUTION! Never install in sleeping rooms, bathrooms, or garages. Ensure adequate ventilation.

Technical Specifications

Operating Instructions

Normal operation procedures and thermostat settings.

  1. Thermostat Setting: Set to HEAT mode and desired temperature.
  2. System Start: Furnace will ignite after thermostat call for heat.
  3. Normal Operation: Listen for proper ignition sequence.
  4. Shutdown: System cycles off when thermostat satisfied.
  5. Pilot Light: Electronic ignition - no standing pilot.

Note: Allow 5-minute delay between shutdown and restart for safety.

Control Settings

Furnace control board settings and adjustments.

ControlFunctionSetting
Gas ValveGas pressure regulationFactory set - do not adjust
Limit SwitchHigh temperature safetyAuto-reset 200°F
Blower SpeedAirflow adjustmentTap settings on motor
Ignition ControlSpark ignition timingFixed timing sequence
Pressure SwitchVent safety verificationProves draft before ignition

Venting System

Proper vent installation and requirements.

  1. Vent Material: Use approved Category I vent pipe.
  2. Vent Size: Match furnace outlet size (check rating plate).
  3. Clearances: Maintain required clearances to combustibles.
  4. Termination: Follow local code for vent termination location.
  5. Slope: Horizontal vents slope upward 1/4" per foot.

WARNING! Improper venting can cause carbon monoxide buildup leading to serious injury or death.

Gas Connections

Gas line installation and pressure testing.

  1. Pipe Size: Minimum 1/2" for natural gas, 3/8" for LP.
  2. Shut-off Valve: Install within 6 feet of furnace.
  3. Drip Leg: Install sediment trap in gas line.
  4. Pressure Test: Test at 14" water column for 10 minutes.
  5. Leak Check: Use soap solution on all connections.

CAUTION! Gas connections must be made by licensed professional only.

Electrical Wiring

Electrical connections and wiring diagrams.

Note: Refer to wiring diagram on furnace door for specific connections.

Maintenance Procedures

Regular maintenance schedule and procedures.

  1. Monthly: Check air filter; replace if dirty.
  2. Seasonal: Inspect burners and heat exchanger.
  3. Annual: Professional inspection and cleaning.
  4. Blower: Clean blower wheel and housing annually.
  5. Vents: Inspect vent system for obstructions.

Recommended: Schedule professional maintenance before each heating season.

Troubleshooting Guide

SymptomPossible CauseCorrective Action
No heatThermostat setting, power, gas supplyCheck thermostat, circuit breaker, gas valve
Blower runs continuouslyThermostat fan setting, limit switchSet thermostat to AUTO, check limit switch
Furnace cycles on limitDirty filter, restricted airflowReplace filter, check vents and registers
No ignitionGas supply, ignition controlCheck gas valve, inspect igniter and flame sensor
Unusual noisesLoose parts, airflow issuesTighten components, check ductwork

Reset Procedure: Turn power off for 30 seconds, then restore.

Warranty Information

Nordyne M1MB furnace warranty coverage.

For warranty service, contact authorized Nordyne dealer with proof of purchase and installation date.