Nordyne Intertherm Electric Furnace Manual

The Nordyne Intertherm Electric Furnace is a high-efficiency heating system designed for residential use, featuring multiple heating elements, integrated blower system, thermal safety controls, and compatibility with standard thermostat controls. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation Requirements 3. Electrical Connections 4. Specifications 5. Controls and Settings 6. Operation Procedures 7. Maintenance Schedule 8. Safety Features 9. Cleaning & Care 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Heating elements, blower assembly, control board, thermal limit switches, transformer, and access panels.

FeatureDescription
Heating ElementsMultiple staged heating elements for efficient operation
Blower AssemblyVariable speed blower for consistent air circulation
Control BoardMicroprocessor-controlled operation with diagnostic LEDs
Thermal Limit SwitchesSafety devices to prevent overheating
Transformer24V control circuit power supply
Access PanelsRemovable panels for service and maintenance
Sequence ControlsStaged heating element activation
Air Flow SwitchEnsures proper airflow before heating
High Limit ControlAutomatic shutdown if temperatures exceed safe limits
Door Safety SwitchDisables operation when access panels are removed

Installation Requirements

Proper installation is critical for safe and efficient operation.

  1. Location: Install in dry, well-ventilated area with adequate clearance
  2. Ductwork: Ensure proper duct sizing and sealing
  3. Electrical: Required 240V AC power supply with appropriate circuit breaker
  4. Thermostat: Compatible 24V thermostat with heat-only operation
  5. Clearances: Maintain minimum clearances as specified in manual

WARNING! Installation must be performed by qualified HVAC technician. Improper installation can cause fire hazard or equipment damage.

Electrical Connections

Follow all local electrical codes and manufacturer specifications.

  1. Disconnect all power before making electrical connections
  2. Connect line voltage wiring to appropriate terminals (L1, L2)
  3. Connect low voltage thermostat wiring (R, W, C, G)
  4. Verify proper grounding and circuit protection
  5. Check all connections for tightness and proper wire sizing

CAUTION! Electrical work should only be performed by licensed electrician. Verify voltage and phase requirements before connection.

Specifications

Controls and Settings

Access control board via front service panel. LED indicators show system status.

Thermostat Connections: R (24V hot), W (heat), G (fan), C (common)

Blower Settings: Adjust blower speed taps for proper airflow. Limit Controls: Automatic reset high limit switches. Element Sequencing: Staged activation based on heating demand. Diagnostic LEDs: Flash codes indicate specific operational status or fault conditions.

Operation Procedures

Normal operation is controlled by thermostat settings.

  1. Set thermostat to desired temperature
  2. System initiates heating sequence when temperature drops below setpoint
  3. Blower activates after warm-up delay
  4. Heating elements stage on as needed to maintain temperature
  5. System cycles off when setpoint is reached

Tip: Allow system to complete full heating cycle before adjusting thermostat settings.

Maintenance Schedule

Regular maintenance ensures optimal performance and longevity.

  1. Monthly: Check and replace air filters
  2. Seasonal: Inspect heating elements and electrical connections
  3. Annual: Professional inspection and cleaning
  4. As needed: Clean blower assembly and check motor bearings
  5. Biannual: Verify safety controls and limit switches

WARNING! Disconnect all power before performing any maintenance. Only qualified technicians should service electrical components.

Safety Features

Multiple safety systems protect against hazardous conditions.

High Limit Switches: Automatic shutdown if temperatures exceed safe limits. Door Safety Interlock: Prevents operation when access panels are removed. Fusible Links: Protect against electrical overloads. Air Flow Monitoring: Ensures proper ventilation before heating activation. Thermal Fuses: Non-resettable protection against overheating.

Cleaning & Care

Regular cleaning maintains efficiency and prevents malfunctions.

Air Filters: Replace monthly during heating season. Blower Assembly: Vacuum annually. Heating Elements: Professional cleaning only. Exterior: Wipe with dry cloth. Condensate Drain: Clear if applicable.

CAUTION! Never use water or cleaning solutions on electrical components. Always disconnect power before cleaning.

Regulatory Information

UL Listed: Complies with UL Standard 1995. CSA Certified: Meets Canadian Standards Association requirements. NEC Compliance: Designed per National Electrical Code. For technical support, contact Nordyne at 1-800-422-4328 or visit www.nordyne.com. Copyright © Nordyne LLC. All rights reserved.

Troubleshooting

SymptomPossible CauseCorrective Action
No heatPower supply, thermostat, limit switchCheck circuit breaker, verify thermostat settings, reset limit switches
Insufficient heatDirty filters, duct issues, element failureReplace filters, check ductwork, test heating elements
Blower not runningMotor, capacitor, control boardCheck motor operation, test capacitor, verify control signals
Frequent cyclingDirty filters, oversized unit, thermostat locationClean/replace filters, verify proper sizing, relocate thermostat
Strange odorsDust accumulation, electrical issuesClean system, inspect electrical connections
Circuit breaker tripsShort circuit, overload, ground faultInspect wiring, check element resistance, verify proper circuit sizing

Reset: Turn power off for 5 minutes then restore. Check diagnostic LED codes.

Service: 1-800-422-4328; www.nordyne.com