The Nordyne Intertherm Furnace is a high-efficiency gas heating system designed for residential use, featuring electronic ignition, multi-speed blower motor, safety controls, and compatibility with various thermostat systems. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Gas valve, heat exchanger, blower assembly, electronic ignition system, safety controls, filter access, and thermostat connections.
| Feature | Description |
|---|---|
| Electronic Ignition | Energy-efficient spark ignition system |
| Multi-speed Blower | Adjustable airflow for optimal heating |
| Safety Controls | Automatic shut-off for overheating |
| Filter Access | Easy-access filter compartment |
| Gas Valve | Precision gas flow control |
| Heat Exchanger | Stainless steel construction |
| Thermostat Connections | Compatible with standard 24V systems |
| Pressure Switch | Ensures proper venting operation |
| Limit Switch | Prevents overheating conditions |
| Flame Sensor | Monitors burner operation |
Unpack and inspect all components. Ensure proper clearances and venting.
WARNING! Gas appliances can be dangerous; installation must be performed by qualified technician. Ensure proper ventilation.
Initial startup and system verification procedures.
CAUTION! Only qualified technicians should perform initial startup and gas connections.
Access control board via front panel. Integrated control module with status lights.
Control Board Indicators: Power LED, Status flash codes, Reset button.
Temperature Settings: Adjust via thermostat. Blower Speed: Factory set for optimal airflow. Gas Pressure: Adjust at gas valve (qualified technician only). Limit Controls: Automatic high-limit protection. Pressure Switch: Ensures venting safety.
Standard 24V thermostat wiring connections at control board.
Tip: Use 18-gauge thermostat wire for best performance.
Normal heating cycle operation and seasonal startup.
WARNING! Never bypass safety controls. If furnace fails to start, wait 5 minutes before retry.
Multiple safety systems protect against hazardous conditions.
Flame Rollout Switch: Detects improper burner flames. High Limit Switch: Prevents overheating. Pressure Switch: Ensures proper venting. Flame Sensor: Confirms burner ignition. Gas Valve: Automatic shut-off capability.
Regular maintenance ensures optimal performance and safety.
CAUTION! Turn off gas and electrical power before any maintenance. Only qualified technicians should service gas components.
ANSI Z21.47: Certified for gas-fired central furnaces. UL listed for safety. CSA approved for Canadian installations. All installations must comply with local building codes and NFPA 54. For technical support, contact Nordyne at 1-800-422-4328 or visit www.nordyne.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power/thermostat | Check circuit breaker; verify thermostat setting; ensure gas valve open. |
| No heat | Ignition failure | Check status lights; verify gas supply; inspect igniter. |
| Blower won't run | Motor/controls | Check blower door switch; verify motor operation; inspect capacitor. |
| Short cycling | Filter/limit switch | Replace dirty filter; check high limit switch; verify airflow. |
| Unusual noises | Mechanical issues | Inspect blower wheel; check motor bearings; verify ductwork. |
Reset: Power cycle furnace at disconnect switch if lockout occurs.
Service: 1-800-422-4328; www.nordyne.com