The Nordyne M1M Furnace is a high-efficiency gas furnace designed for residential heating applications. This manual covers the M1M series with features including multi-speed blower operation, electronic ignition, diagnostic LED system, safety controls, and compatibility with various thermostat types. Below are key sections for safety, installation, operation, maintenance, and troubleshooting.
Key components: Gas valve, heat exchanger, blower assembly, control board, pressure switches, igniter, flame sensor.
| Feature | Description |
|---|---|
| Multi-speed blower | Variable speed operation for optimal airflow |
| Electronic ignition | Hot surface igniter for reliable startup |
| Diagnostic LED | Flashing codes for troubleshooting |
| Safety controls | Pressure switches, rollout switches, flame sensor |
| Gas valve | Regulates natural gas or propane flow |
| Heat exchanger | Stainless steel construction for efficiency |
| Filter access | Easy-access filter compartment |
| Control board | Integrated furnace controller |
| Thermostat connections | Standard 24V thermostat terminals |
| Service switches | Power disconnect and door safety switch |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas appliances can be hazardous; installation must comply with all local codes and regulations.
Complete installation verification before initial startup.
CAUTION! Only qualified technicians should perform startup procedures.
Access control board via front panel removal. Thermostat controls heating cycles.
Control Board: Diagnostic LED, terminal connections, dip switches for configuration.
Operation Sequence: Thermostat call for heat → inducer motor starts → pressure switch proves → igniter heats → gas valve opens → flame sensor confirms → blower starts after delay.
Settings: Blower speeds (heating/cooling), temperature rise adjustment, fan on/off delays.
Proper venting critical for safe operation. Category I venting required.
Tip: Regular inspection of vent system prevents blockage and ensures safety.
Annual professional maintenance recommended. Monthly filter changes.
WARNING! Disconnect power before performing any maintenance.
Multiple safety systems protect against hazardous conditions.
| Safety Device | Function |
|---|---|
| Flame rollout switch | Detects flame outside combustion chamber |
| Pressure switches | Verify proper venting airflow |
| Flame sensor | Confirms burner ignition |
| High limit switch | Prevents overheating |
| Gas valve | Automatic shutoff if flame not detected |
| Door safety switch | Disables operation when panel removed |
ANSI Z21.47: Certified for US and Canadian standards. CSA International approved. UL listed. Installation must comply with National Fuel Gas Code (NFPA 54) and local building codes. For technical support, contact Nordyne at 1-800-422-4328 or visit www.nordyne.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat settings, door panel secure |
| No heat | Gas supply, igniter, flame sensor | Verify gas valve on, check igniter operation, clean flame sensor |
| Short cycling | Dirty filter, high limit | Replace filter, check airflow, verify limit switch operation |
| Blower won't run | Motor, capacitor, control board | Check motor voltage, test capacitor, verify control signals |
| Lockout condition | Safety device tripped | Reset power, check diagnostic LED codes, clear fault |
| Unusual noises | Blower, inducer, ductwork | Inspect blower wheel, check inducer motor, examine duct connections |
Diagnostic Codes: Refer to control board LED flash patterns for specific error codes.
Service: 1-800-422-4328; www.nordyne.com