The Nordyne Intertherm FEH-015HA-01 is a high-efficiency gas furnace designed for residential heating applications. This 15,000 BTU unit features electronic ignition, multi-speed blower motor, safety controls, and compatibility with standard thermostat systems. Below are key sections for safety, installation, operation, maintenance, and troubleshooting.
Important safety precautions for proper furnace operation and maintenance.
| Warning Type | Description |
|---|---|
| Fire Hazard | Keep combustible materials away from furnace |
| Carbon Monoxide | Ensure proper ventilation and exhaust |
| Electrical Shock | Disconnect power before servicing |
| Burn Hazard | Surfaces become hot during operation |
| Gas Leaks | Check for gas leaks before operation |
Proper installation procedures for safe and efficient operation.
WARNING! Installation must be performed by qualified technician only.
Proper startup and shutdown procedures for normal operation.
CAUTION! Do not attempt to manually override safety controls.
Access control board via front panel. LED indicators show system status.
Control Board: POWER ON/OFF, SYSTEM RESET, DIAGNOSTIC LIGHTS.
Blower Speed: Adjustable via dip switches on control board. Gas Pressure: Factory set - do not adjust. Limit Controls: Automatic high-limit protection. Ignition System: Electronic hot surface igniter.
Regular maintenance schedule for optimal performance.
Tip: Replace air filter every 3 months during heating season.
Standard wiring configuration for thermostat and power connections.
| Terminal | Function | Wire Color |
|---|---|---|
| R | 24V Power | Red |
| W | Heat | White |
| G | Fan | Green |
| C | Common | Blue |
| Y | Cooling | Yellow |
WARNING! All electrical work must comply with local codes.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Thermostat setting/power | Check thermostat setting; verify power supply; check circuit breaker |
| Blower not running | Motor/control board | Check blower motor; inspect control board; verify fan setting |
| Furnace short cycling | Dirty filter/limit switch | Replace air filter; check high-limit switch; verify airflow |
| Gas odor | Leaks/improper combustion | Immediately shut off gas; call qualified technician |
| Unusual noises | Loose components | Check for loose panels; inspect blower wheel; verify duct connections |
Reset: Power cycle unit if lockout occurs.
Common replacement parts for FEH-015HA-01 furnace.
Limited warranty coverage for FEH-015HA-01 furnace.
Heat Exchanger: 20-year limited warranty. Parts: 5-year limited warranty. Labor: 1-year from date of installation. Registration: Complete and return warranty card within 60 days. For service, contact Nordyne at 1-800-422-4328 or visit www.nordyne.com.