owners manual for nordyne intertherm furnace feh 9303-01395

The Nordyne Intertherm FEH 9303-01395 is a high-efficiency gas furnace designed for residential heating applications. This furnace features advanced combustion technology, multiple heating stages, electronic ignition, variable-speed blower motor, and comprehensive safety controls. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to HVAC System 7. Operating Procedures 8. Safety Features 9. Maintenance & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Gas valve assembly, heat exchanger, blower assembly, control board, ignition system, safety switches, and venting system.

FeatureDescription
Gas ValvePrecision gas flow control with multiple stages
Heat ExchangerStainless steel construction for durability and efficiency
Blower AssemblyVariable-speed ECM motor for quiet operation
Control BoardMicroprocessor-based for precise temperature control
Ignition SystemElectronic hot surface ignition
Pressure SwitchesSafety monitoring of combustion air flow
Limit SwitchesOver-temperature protection
Flame SensorVerifies burner ignition
Venting SystemPVC pipe compatible for sidewall or roof venting
Filter SystemStandard 1-inch or 4-inch media filter compatible

Installation

Unpack and inspect all components. Ensure proper clearances and level installation surface.

  1. Position furnace: Place on stable, level surface with proper clearances (6 inches minimum from combustible materials).
  2. Gas connection: Use approved gas piping and fittings; pressure test for leaks.
  3. Electrical connection: Connect to 120V AC power supply with proper grounding.
  4. Venting: Install PVC vent pipes according to local codes and manufacturer specifications.
  5. Ductwork: Connect supply and return ducts securely.
  6. Thermostat: Connect compatible 24V thermostat wires to control board.

WARNING! Installation must be performed by qualified HVAC technician. Gas leaks can cause explosion or fire.

First-Time Setup

After installation, perform initial startup and system configuration.

  1. Gas pressure adjustment: Set manifold pressure to 3.5" WC for natural gas.
  2. Blower speed settings: Adjust dip switches for proper airflow (CFM).
  3. Thermostat configuration: Set up heating stages and fan control.
  4. System check: Verify proper ignition sequence and flame operation.
  5. Safety testing: Test all limit switches and safety controls.

CAUTION! Never bypass safety controls. Ensure proper combustion air supply.

Specifications

Controls and Settings

Access control board via front panel. LED status lights indicate system operation and error codes.

Control Board: Power switch, fuse, diagnostic LED, dip switches for configuration.

Heating Stages: Low fire and high fire operation based on demand. Blower Control: Variable speed for optimal airflow and comfort. Temperature Limits: Auto-reset and manual reset limit switches. Diagnostic Codes: Flash patterns indicate specific system status and faults.

Connecting to HVAC System

Proper integration with existing HVAC components and thermostat.

  1. Turn off power to furnace before making connections.
  2. Thermostat wiring: Connect R, W, G, C terminals according to wiring diagram.
  3. Humidifier: Connect to HUM terminal if equipped.
  4. Air cleaner: Connect electronic air cleaner to appropriate terminals.
  5. Zone control: Compatible with most zoning systems.

Tip: Use only compatible thermostats designed for two-stage gas furnaces.

Operating Procedures

Normal heating operation and seasonal startup.

  1. Power on: Turn furnace power switch to ON position.
  2. Thermostat call: Set thermostat above room temperature to initiate heating cycle.
  3. Ignition sequence: Inducer motor starts, pressure switch closes, igniter glows, gas valve opens.
  4. Flame verification: Flame sensor confirms ignition, main burners operate.
  5. Blower operation: Blower starts after heat exchanger warm-up delay.
  6. Cycle completion: System shuts down when thermostat satisfied.

WARNING! Never operate furnace with access panels removed. Keep combustible materials away from furnace.

Safety Features

Multiple safety systems protect against hazardous conditions. Flame Rollout Switches: Detect improper burner flames. High Limit Switches: Prevent overheating. Pressure Switches: Ensure proper venting. Flame Sensor: Confirms burner ignition. Gas Valve: Automatic shutoff if ignition fails.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and safety.

  1. Monthly: Check and replace air filter as needed.
  2. Annual: Professional inspection and cleaning of burners, heat exchanger, and vent system.
  3. Seasonal: Verify proper system operation before heating season.
  4. Blower maintenance: Clean blower wheel and motor annually.

CAUTION! Turn off power and gas supply before performing any maintenance. Only qualified technicians should service gas components.

Regulatory Information

UL listed and ANSI certified for safety. Complies with ASHRAE standards for residential gas furnaces. Manufactured to meet DOE energy efficiency requirements. For technical support, contact Nordyne at 1-800-422-4328 or visit www.nordyne.com. This product must be installed by qualified personnel in accordance with all local codes and ordinances.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower, thermostat, door switchCheck power supply; verify thermostat setting; ensure door switches engaged.
No heatGas supply, ignition, limit switchVerify gas valve open; check for ignition failure; reset limit switches.
Short cyclingDirty filter, airflow, overheatingReplace air filter; check for blocked vents; verify proper airflow.
Blower won't stopThermostat, control boardCheck thermostat fan setting; inspect control board relay.
Error codes flashingVarious system faultsRefer to diagnostic chart in service manual; count LED flashes.

Reset: Turn power off for 30 seconds, then restart.

Service: 1-800-422-4328; www.nordyne.com