The Nordyne Intertherm FEH 9303-01395 is a high-efficiency gas furnace designed for residential heating applications. This furnace features advanced combustion technology, multiple heating stages, electronic ignition, variable-speed blower motor, and comprehensive safety controls. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Gas valve assembly, heat exchanger, blower assembly, control board, ignition system, safety switches, and venting system.
| Feature | Description |
|---|---|
| Gas Valve | Precision gas flow control with multiple stages |
| Heat Exchanger | Stainless steel construction for durability and efficiency |
| Blower Assembly | Variable-speed ECM motor for quiet operation |
| Control Board | Microprocessor-based for precise temperature control |
| Ignition System | Electronic hot surface ignition |
| Pressure Switches | Safety monitoring of combustion air flow |
| Limit Switches | Over-temperature protection |
| Flame Sensor | Verifies burner ignition |
| Venting System | PVC pipe compatible for sidewall or roof venting |
| Filter System | Standard 1-inch or 4-inch media filter compatible |
Unpack and inspect all components. Ensure proper clearances and level installation surface.
WARNING! Installation must be performed by qualified HVAC technician. Gas leaks can cause explosion or fire.
After installation, perform initial startup and system configuration.
CAUTION! Never bypass safety controls. Ensure proper combustion air supply.
Access control board via front panel. LED status lights indicate system operation and error codes.
Control Board: Power switch, fuse, diagnostic LED, dip switches for configuration.
Heating Stages: Low fire and high fire operation based on demand. Blower Control: Variable speed for optimal airflow and comfort. Temperature Limits: Auto-reset and manual reset limit switches. Diagnostic Codes: Flash patterns indicate specific system status and faults.
Proper integration with existing HVAC components and thermostat.
Tip: Use only compatible thermostats designed for two-stage gas furnaces.
Normal heating operation and seasonal startup.
WARNING! Never operate furnace with access panels removed. Keep combustible materials away from furnace.
Multiple safety systems protect against hazardous conditions. Flame Rollout Switches: Detect improper burner flames. High Limit Switches: Prevent overheating. Pressure Switches: Ensure proper venting. Flame Sensor: Confirms burner ignition. Gas Valve: Automatic shutoff if ignition fails.
Regular maintenance ensures optimal performance and safety.
CAUTION! Turn off power and gas supply before performing any maintenance. Only qualified technicians should service gas components.
UL listed and ANSI certified for safety. Complies with ASHRAE standards for residential gas furnaces. Manufactured to meet DOE energy efficiency requirements. For technical support, contact Nordyne at 1-800-422-4328 or visit www.nordyne.com. This product must be installed by qualified personnel in accordance with all local codes and ordinances.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check power supply; verify thermostat setting; ensure door switches engaged. |
| No heat | Gas supply, ignition, limit switch | Verify gas valve open; check for ignition failure; reset limit switches. |
| Short cycling | Dirty filter, airflow, overheating | Replace air filter; check for blocked vents; verify proper airflow. |
| Blower won't stop | Thermostat, control board | Check thermostat fan setting; inspect control board relay. |
| Error codes flashing | Various system faults | Refer to diagnostic chart in service manual; count LED flashes. |
Reset: Turn power off for 30 seconds, then restart.
Service: 1-800-422-4328; www.nordyne.com