RPJ II Furnace Manual

The RPJ II Furnace is a high-efficiency residential heating system with advanced combustion technology, variable-speed blower motor, electronic ignition, built-in diagnostics, multiple heating stages, and smart thermostat compatibility. Designed for natural gas or propane operation with AFUE ratings up to 98%, this furnace features durable stainless steel heat exchangers, quiet operation, and comprehensive safety controls. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Components 7. Operating Procedures 8. Maintenance Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Stainless steel heat exchanger, variable-speed blower motor, electronic ignition system, control board with diagnostics, gas valve, pressure switches, flame sensor, and thermostat connections.

FeatureDescription
Heat ExchangerStainless steel construction for durability and efficiency
Blower MotorVariable-speed ECM motor for quiet operation
Ignition SystemElectronic hot surface ignition
Control BoardMicroprocessor with LED diagnostic codes
Gas ValveModulating for precise temperature control
Pressure SwitchesSafety verification of proper venting
Flame SensorConfirms burner ignition
Thermostat ConnectionsCompatible with conventional and smart thermostats
Air FilterStandard 1-inch or 4-inch media filter compatible
Vent ConnectionsPVC piping for direct vent operation

Installation

Unpack and inspect contents. Position in approved location with proper clearances.

  1. Gas connection: Use approved gas piping; pressure test for leaks before connection.
  2. Electrical connection: Connect to 120V AC power with proper grounding.
  3. Vent system: Install PVC vent pipes according to manufacturer specifications.
  4. Ductwork: Connect supply and return ducts with proper sealing.
  5. Condensate drain: Route to approved drain location.

WARNING! Installation must be performed by qualified HVAC technician. Gas leaks can cause explosion or fire. Ensure proper ventilation and combustion air supply.

First-Time Setup

Power on furnace; follow startup sequence.

  1. System check: Verify all connections are secure and proper.
  2. Gas pressure adjustment: Set manifold pressure to specifications.
  3. Blower speed settings: Adjust for proper airflow and temperature rise.
  4. Thermostat configuration: Program heating cycles and fan operation.
  5. Test operation: Run through complete heating cycle to verify performance.

CAUTION! Never bypass safety controls. Ensure proper combustion air and venting before operation.

Specifications

Controls and Settings

Access control board via front panel. LED status lights indicate system operation and fault codes.

Thermostat Controls: HEAT/COOL/OFF mode selection, temperature setpoint, fan AUTO/ON operation, system programming.

Heating Stages: Single-stage (on/off), two-stage (low/high heat), modulating (incremental heat). Blower Settings: Adjustable speeds for heating and continuous fan operation. Diagnostic Codes: LED flash patterns indicate specific system faults and operational status.

Connecting Components

Gas supply: Black iron pipe with sediment trap. Electrical: 120V AC power with disconnect switch. Thermostat: 2-wire to 8-wire compatible.

  1. Turn off gas and electrical power before making connections.
  2. Match wire colors to terminal designations (R, W, Y, G, C).
  3. Use proper pipe sealant for gas connections - no Teflon tape.
  4. Ensure vent pipes slope properly toward furnace for condensate drainage.

Tip: Always use a manometer to verify proper gas pressure settings after installation.

Operating Procedures

Normal heating operation with thermostat control.

  1. Set thermostat to HEAT mode and desired temperature.
  2. System initiates: Inducer motor starts, pressure switch verifies, igniter heats.
  3. Gas valve opens, burner ignites, flame sensor confirms.
  4. Blower motor starts after heat exchanger warm-up delay.
  5. System cycles off when thermostat setpoint is reached.
  6. Blower continues running during post-purge cycle.

WARNING! Never operate furnace with access panels removed. Keep combustible materials away from furnace. Install carbon monoxide detectors in living areas.

Maintenance Features

Self-diagnostics: LED fault codes indicate specific issues. Filter monitoring: Reminder for regular filter changes. Safety shutdown: Automatic shutoff for unsafe conditions.

Care & Cleaning

Turn off power before servicing. Replace air filters monthly during heating season. Annual professional inspection recommended.

CAUTION! Do not use compressed air to clean heat exchanger. Never operate without air filter. Keep burners and flame sensor clean.

Regulatory Information

ANSI Z21.47: Certified for gas-fired central furnaces. UL 1995: Standard for heating and cooling equipment. Meets DOE energy efficiency standards. For support, contact manufacturer technical service at 1-800-555-HEAT or visit www.rpjfurnace.com.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower/thermostat/safety lockoutCheck circuit breaker; verify thermostat settings; reset power.
No heatGas supply/ignitionVerify gas valve on; check pilot/igniter; inspect flame sensor.
Short cyclingDirty filter/overheatingReplace air filter; check airflow restrictions; verify temperature rise.
Blower not runningMotor/control boardCheck capacitor; verify control board signals; inspect motor.
Unusual noisesMechanical issuesInspect blower wheel; check inducer motor; verify heat exchanger.

Reset: Power cycle furnace at disconnect switch or circuit breaker.

Service: 1-800-555-HEAT; www.rpjfurnace.com