The Ruud 80 Plus Furnace is a high-efficiency gas furnace with AFUE ratings up to 80%, featuring electronic ignition, multi-speed blower motor, durable heat exchanger, safety controls, and compatibility with standard thermostat systems. Designed for residential heating applications with natural gas or propane capability. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Heat exchanger, blower assembly, gas valve, ignition system, pressure switches, limit controls, filter rack.
| Feature | Description |
|---|---|
| Heat Exchanger | Durable aluminized steel construction |
| Blower Motor | Multi-speed ECM or PSC motor |
| Ignition System | Hot surface or intermittent pilot |
| Gas Valve | Automatic gas flow regulation |
| Pressure Switches | Verify proper venting operation |
| Limit Controls | Prevent overheating conditions |
| Filter Rack | Standard 1-inch or 4-inch media filter |
| Control Board | Integrated furnace controller |
| Drain System | Condensate removal for high-efficiency models |
| Thermostat Connection | Standard 24VAC control wiring |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas appliances can be hazardous; installation must comply with all codes. Use qualified HVAC technician.
Professional startup procedure required.
CAUTION! Never bypass safety controls. Carbon monoxide hazard possible with improper installation.
Thermostat controls furnace operation. Integrated control board manages safety sequences.
Operation Sequence: Thermostat call for heat > inducer motor start > pressure switch verification > ignition sequence > gas valve opening > flame verification > blower activation.
User Controls: Thermostat temperature setting, system switch (heat/off/cool), fan switch (auto/on). Service Controls: Diagnostic LED, pressure tap ports, gas valve adjustment.
Proper venting critical for safe operation.
Tip: Keep vent terminals clear of snow, debris, and obstructions.
Regular maintenance ensures efficiency and safety.
WARNING! Turn off power and gas supply before servicing. Use qualified technician for complex maintenance.
Multiple safety systems protect against hazardous conditions.
| Safety Device | Function |
|---|---|
| Flame Rollout Switch | Detects improper burner flames |
| High Limit Switch | Prevents overheating |
| Pressure Switches | Verify venting operation |
| Flame Sensor | Confirms burner ignition |
| Gas Valve | Automatic gas shutoff |
| Ignition Control | Safe ignition sequencing |
Regular cleaning maintains performance and efficiency.
Exterior: Wipe with damp cloth. Interior: Professional cleaning recommended. Filter: Replace regularly. Burners: Clean annually. Drain System: Flush with clean water.
CAUTION! Never use chemical cleaners inside furnace. Keep area around furnace clean and dry.
UL listed. ANSI Z21.47 compliant. CSA certified. Meets U.S. Department of Energy efficiency standards. Installation must comply with National Fuel Gas Code (NFPA 54), National Electrical Code (NFPA 70), and local codes. For support, contact Ruud Customer Service at 1-800-848-4070 or visit www.ruud.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, safety lockout | Check power supply; verify thermostat setting; reset power. |
| No heat | Gas supply, ignition, filter | Verify gas valve on; check filter; inspect ignition system. |
| Short cycling | Filter, limit switch, airflow | Replace filter; check airflow; verify limit switch operation. |
| Blower won't stop | Thermostat, control board | Check thermostat fan setting; inspect control board. |
| Unusual noises | Blower, inducer, ductwork | Inspect blower wheel; check inducer motor; examine ducts. |
| Error codes | Safety lockout, sensor failure | Refer to diagnostic chart; reset if safe; call technician. |
Reset: Turn power off for 30 seconds, then restore.
Service: 1-800-848-4070; www.ruud.com