The Ruud Gas Furnace is a high-efficiency heating system designed for residential applications, featuring advanced combustion technology, variable-speed blower motors, and multiple safety controls. This manual covers proper installation procedures, safety requirements, electrical connections, gas line connections, venting systems, startup procedures, and maintenance guidelines for optimal performance and safety compliance.
Critical safety information for proper furnace installation and operation.
| Hazard | Precaution |
|---|---|
| Gas Leaks | Check all connections with leak detection solution |
| Carbon Monoxide | Ensure proper venting and combustion air supply |
| Electrical Shock | Disconnect power before servicing |
| Fire Hazard | Maintain proper clearances from combustible materials |
| Burn Risk | Allow unit to cool before handling components |
Essential preparations before beginning furnace installation.
WARNING! Installation must comply with all local building codes and NFPA 54/ANSI Z223.1 standards.
Proper furnace placement is critical for safety and performance.
CAUTION! Do not install in areas containing corrosive chemicals or flammable vapors.
Proper gas line installation procedures.
WARNING! Gas piping must be sized according to NFPA 54. Maximum inlet pressure 14" W.C.
Electrical connection requirements and procedures.
| Connection | Specification |
|---|---|
| Line Voltage | 120V, 15A dedicated circuit |
| Thermostat | 24V, 18-22 gauge wire |
| Grounding | Proper equipment grounding required |
| Disconnect | Service disconnect within sight of unit |
| Blower Motor | Variable speed ECM motor |
Vent pipe installation guidelines.
CAUTION! Vent system must terminate at approved location away from windows and air intakes.
Proper duct system connection procedures.
Tip: Measure static pressure to verify proper duct sizing.
Step-by-step furnace startup and verification.
WARNING! Never bypass safety controls during startup. Follow manufacturer's sequence exactly.
Final verification and system testing.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No ignition | Gas supply, igniter, pressure switch | Check gas valve, replace igniter, verify pressure switch operation |
| Short cycling | Dirty filter, airflow restriction | Replace filter, check ductwork, verify proper airflow |
| Blower not running | Motor, capacitor, control board | Check voltage to motor, test capacitor, inspect control board |
| Lockout condition | Flame sensor, gas valve | Clean flame sensor, check gas valve operation |
| Excessive noise | Blower wheel, motor bearings | Inspect blower wheel balance, lubricate or replace motor |
Reset: Power cycle unit to clear lockout conditions.
Service: Contact authorized Ruud dealer for technical support and warranty service.