Ruud Oil Furnace Owners Manual

The Ruud Oil Furnace is a high-efficiency heating system designed for residential use, featuring advanced combustion technology, safety controls, and energy-efficient operation. This manual covers installation guidelines, operation procedures, maintenance requirements, troubleshooting tips, and safety precautions for proper furnace operation and longevity.

1. Features at a Glance 2. Installation Requirements 3. First-Time Setup 4. Technical Specifications 5. Controls and Settings 6. Operating Procedures 7. Maintenance Schedule 8. Safety Features 9. Cleaning & Servicing 10. Regulatory Information 11. Troubleshooting Guide

Features at a Glance

Key components: Combustion chamber, oil burner assembly, heat exchanger, blower motor, safety controls, thermostat connection, flue outlet.

FeatureDescription
Combustion ChamberHigh-temperature refractory lined for efficient burning
Oil Burner AssemblyPrecision nozzle and electrode system for optimal flame
Heat ExchangerStainless steel construction for maximum heat transfer
Blower MotorVariable speed for quiet operation and energy efficiency
Safety ControlsPrimary control, limit switches, pressure regulator
Thermostat ConnectionStandard 24V connection for home thermostat
Flue OutletProper venting for combustion gases
Oil FilterRemoves contaminants from fuel line
Ignition SystemHigh-voltage electronic ignition
Cad CellFlame detection safety device

Installation Requirements

Professional installation recommended. Ensure proper clearances and ventilation.

  1. Location: Install in dry, well-ventilated area with proper clearances to combustibles.
  2. Venting: Proper flue pipe installation with correct slope and termination.
  3. Oil Supply: Install oil line with shut-off valve and proper filter.
  4. Electrical: Connect to dedicated 120V circuit with proper grounding.
  5. Thermostat: Install compatible 24V thermostat with heat anticipator setting.

WARNING! Installation must comply with local codes and regulations. Only qualified technicians should perform installation.

First-Time Setup

Initial startup and system verification by qualified technician.

  1. System Check: Verify all connections, oil supply, and electrical power.
  2. Priming: Prime oil line and bleed air from system.
  3. Ignition Test: Verify proper burner ignition and flame pattern.
  4. Temperature Settings: Set thermostat and verify system cycling.
  5. Safety Test: Verify all safety controls are functioning properly.

CAUTION! Never attempt first-time startup without proper training and equipment.

Technical Specifications

Controls and Settings

Primary control module with safety functions and operational settings.

Primary Control: POWER ON/OFF, RESET button, status lights, timing functions.

Thermostat Settings: HEAT/COOL/OFF, temperature setpoint, fan AUTO/ON. Limit Controls: High limit switch, fan control, safety roll-out switch. Pressure Regulator: Adjustable oil pressure setting. Blower Control: Multi-speed settings for different duct systems.

Operating Procedures

Normal operation through thermostat control with automatic safety monitoring.

  1. Set thermostat to desired temperature in HEAT mode.
  2. System will automatically start when room temperature drops below setpoint.
  3. Burner ignites, heat exchanger warms, blower circulates warm air.
  4. System cycles off when temperature reaches setpoint.
  5. Monitor for normal operation sounds and consistent heating.

Tip: Keep thermostat away from heat sources and drafts for accurate temperature control.

Maintenance Schedule

Regular professional maintenance required for optimal performance and safety.

  1. Annual Service: Complete cleaning and inspection by qualified technician.
  2. Monthly: Check and replace air filters as needed.
  3. Seasonal: Inspect oil tank, lines, and filter for contaminants.
  4. Bi-annual: Check and clean heat exchanger surfaces.
  5. As needed: Clean burner assembly and nozzle replacement.

WARNING! Neglecting maintenance can lead to inefficient operation, safety hazards, and premature failure.

Safety Features

Multiple safety systems protect against hazardous conditions. Stack Relay: Monitors draft and combustion. Limit Switches: Prevent overheating. Pressure Regulator: Maintains proper oil pressure. Cad Cell: Detects flame presence for safe operation. Roll-out Switch: Protects against flame roll-out condition.

Cleaning & Servicing

Professional cleaning required. Turn off power and fuel supply before servicing.

CAUTION! Never attempt internal cleaning without proper training. Contact qualified service technician for all internal maintenance.

Regulatory Information

UL listed and complies with ANSI Z21.47 standards for oil-fired central furnaces. Manufactured to meet EPA efficiency requirements. All installations must comply with National Fuel Gas Code NFPA 54 and local building codes. For technical support, contact Ruud Customer Service at 1-800-848-3074 or visit www.ruud.com.

Troubleshooting Guide

SymptomPossible CauseCorrective Action
No heatPower outage, thermostat setting, safety lockoutCheck power supply; verify thermostat setting; reset primary control.
Burner won't igniteNo fuel, ignition failure, cad cell dirtyCheck oil supply; verify ignition system; clean cad cell eye.
Frequent cyclingDirty filter, limit switch, airflow restrictionReplace air filter; check limit switch; verify ductwork clear.
Smoke or odorsDirty burner, improper combustionShut down immediately; call for professional service.
Unusual noisesMotor bearings, blower wheel, combustion issuesIdentify noise source; schedule professional inspection.

Reset Procedure: Press RESET button on primary control once only. If problem persists, call for service.

Service: 1-800-848-3074; www.ruud.com