The Ruud Silhouette 2 is a high-efficiency gas furnace featuring advanced combustion technology, variable-speed blower motor, electronic ignition system, multi-speed airflow control, built-in diagnostic system, quiet operation design, energy-efficient performance, and compatibility with most thermostats. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Variable-speed ECM blower motor, hot surface igniter, flame sensor, pressure switches, gas valve, heat exchanger, condensate drain system.
| Feature | Description |
|---|---|
| Variable-speed blower | Provides consistent airflow and quiet operation |
| Electronic ignition | Hot surface igniter for reliable startup |
| Multi-position installation | Can be installed in upflow, downflow, or horizontal configurations |
| Diagnostic LED | Flashing codes for troubleshooting |
| Secondary heat exchanger | Stainless steel for high efficiency |
| Condensate drain system | Removes combustion byproducts |
| Gas valve | Precise fuel control |
| Flame sensor | Monitors burner operation |
| Pressure switches | Ensures proper venting |
| Thermal limit switches | Prevents overheating |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas furnaces produce carbon monoxide; proper venting is critical. Installation must comply with all local codes.
Initial startup must be performed by qualified technician.
CAUTION! Never operate furnace without proper venting. Keep combustibles away from furnace.
Integrated control board with diagnostic capabilities. Access via door removal.
Thermostat Connections: R (24V), C (Common), W (Heat), G (Fan), Y (Cool)
Control Board: POWER switch, diagnostic LED, dip switches for blower speed settings, pressure switch terminals, gas valve connector, igniter connections.
Blower Speeds: Adjustable for heating and cooling modes via dip switches. Temperature Rise: Must be within range on rating plate (typically 30-60°F).
Direct vent system using PVC pipe for intake and exhaust.
Tip: Install condensate drain trap and ensure proper drainage away from foundation.
Normal operation controlled by thermostat.
WARNING! If you smell gas, turn off gas supply immediately and call professional. Do not operate until leak is repaired.
Annual maintenance by qualified technician recommended.
Monthly: Check air filter; replace when dirty (typically 1-3 months).
Annual Professional Service: Clean heat exchanger, check burners, verify gas pressure, inspect vent system, test safety controls, check condensate system, lubricate motor if required.
CAUTION! Turn off power and gas before servicing. Only qualified personnel should perform internal maintenance.
Multiple safety systems protect against hazardous conditions.
| Safety Feature | Function |
|---|---|
| Flame rollout switches | Detects flame outside combustion chamber |
| High limit switch | Prevents overheating |
| Pressure switches | Ensures proper venting before ignition |
| Flame sensor | Confirms burner ignition |
| Ignition control | Limits trial-for-ignition period |
| Gas valve | Automatic shutoff if no flame detected |
ANSI Z21.47: Certified for natural and propane gas operation. UL listed. Meets DOE energy efficiency standards. CSA design-certified. For technical support, contact Ruud at 1-800-722-2102 or visit www.ruud.com. Installation must comply with National Fuel Gas Code NFPA 54/ANSI Z223.1 and local codes.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat settings, ensure door properly closed. |
| No heat | Gas supply, igniter, flame sensor | Verify gas valve on, check for dirty flame sensor, inspect igniter. |
| Short cycling | Dirty filter, high limit | Replace air filter, check for restricted airflow. |
| Blower won't stop | Thermostat fan setting | Check thermostat fan setting (ON vs AUTO). |
| Error codes (flashing LED) | Various faults | Count flashes and refer to diagnostic chart in manual. |
| Condensate leak | Clogged drain line | Clear condensate drain and trap. |
Reset: Turn power off for 30 seconds, then restore. If problem persists, call professional.
Service: 1-800-722-2102; www.ruud.com