The Ruud Silhouette II Gas Furnace is a high-efficiency residential heating system featuring advanced combustion technology, variable-speed blower motor, electronic ignition system, multi-speed inducer motor, and comprehensive safety controls. This manual provides detailed parts identification, replacement procedures, and technical specifications for proper maintenance and repair. Below are key sections for parts overview, installation guidelines, troubleshooting, and replacement procedures.
Key components: Heat exchanger assembly, Gas valve, Burners, Inducer motor, Blower motor, Control board, Igniter, Flame sensor, Pressure switches, Thermostat connections.
| Component | Description |
|---|---|
| Heat Exchanger | Primary and secondary heat transfer surfaces |
| Gas Valve | Regulates gas flow to burners |
| Burner Assembly | Stainless steel burners with ports |
| Inducer Motor | Draft inducer for combustion gases |
| Blower Motor | Variable-speed circulating air blower |
| Control Board | Main system controller with diagnostic LEDs |
| Hot Surface Igniter | Silicon carbide ignition element |
| Flame Sensor | Proves flame during operation |
| Pressure Switches | Verify proper venting operation |
| Limit Switches | High temperature safety controls |
Proper installation ensures safe and efficient operation.
WARNING! Gas furnaces produce carbon monoxide; proper venting is critical for safety. Only qualified technicians should perform installation.
Front access panel removal provides access to major components. Upper compartment contains heat exchanger and burners; lower compartment contains blower assembly.
Upper Section: Gas valve, manifold, burners, igniter, flame sensor, inducer motor, pressure switches, primary limit control.
Lower Section: Blower motor, control board, transformer, blower door switch, filter rack, auxiliary drain connection.
Always disconnect power and gas supply before servicing.
CAUTION! Use only Ruud-approved replacement parts to maintain safety and efficiency.
Control board with diagnostic LED codes, 24V transformer, blower motor (ECM), inducer motor, pressure switches, limit controls, rollout switches, door interlock switch.
Tip: Check fuse on control board before replacing components.
Gas valve with manual shutoff, manifold, burners, orifice holders, pilot assembly (if equipped).
WARNING! Always leak test after any gas connection work. Use soap solution to check for bubbles.
PVC intake and exhaust pipes, couplings, elbows, termination kits.
Venting Guidelines: Maximum equivalent length 100 feet, minimum 5 feet. Maintain 1/4" per foot slope back to furnace. Keep intake and exhaust terminations at same pressure zone.
Flame rollout switches, high limit switches, pressure switches, door interlock switch, igniter safety timing, gas valve safety shutoff.
Annual professional inspection recommended. Monthly filter changes during heating season. Visual inspection of vent pipes and drain lines.
CAUTION! Only qualified HVAC technicians should perform internal component maintenance.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat setting, door switch engagement. |
| No heat | Igniter, gas valve, flame sensor | Test igniter for continuity, check gas valve operation, clean flame sensor. |
| Blower won't run | Motor, capacitor, control board | Check voltage to motor, test capacitor, verify control board signal. |
| Short cycling | Filter, limit switch, airflow | Replace filter, check limit switch, verify proper airflow. |
| Error codes flashing | Various system faults | Refer to control board LED flash pattern in service manual. |
Reset: Power cycle unit to clear temporary lockouts.
Service: Contact authorized Ruud dealer for technical support and genuine parts.