Suburban Furnace Installation Manual

The Suburban Furnace is a high-efficiency heating system designed for residential and light commercial applications. This manual covers the SF-20 series with natural gas/LP gas compatibility, electronic ignition, variable speed blower, multi-position installation capability, built-in safety controls, diagnostic LED system, and energy efficiency ratings up to 95% AFUE. Below are key sections for safety, installation procedures, electrical connections, gas connections, startup, operation, maintenance, and troubleshooting.

1. Safety Precautions 2. Pre-Installation Requirements 3. Installation Procedures 4. Electrical Connections 5. Gas Connections 6. Venting Requirements 7. Startup and Commissioning 8. Operating Instructions 9. Maintenance Schedule 10. Troubleshooting Guide 11. Technical Specifications

Safety Precautions

Critical safety information for proper installation and operation.

Hazard TypePrecaution
Fire/ExplosionInstall in well-ventilated area away from combustible materials
Carbon MonoxideEnsure proper venting and annual inspection
Electrical ShockDisconnect power before servicing
Gas LeaksUse leak detection solution on all connections
BurnsAllow unit to cool before handling

WARNING! Installation must comply with local codes and NFPA 54/ANSI Z223.1.

Pre-Installation Requirements

Site preparation and necessary tools.

  1. Location: Minimum clearances - 24" front, 6" sides, 12" top, 6" rear.
  2. Combustion Air: Ensure adequate fresh air supply per local codes.
  3. Floor Protection: Required for combustible flooring.
  4. Tools Needed: Pipe wrenches, manifold gauge, voltmeter, leak detector.

CAUTION! Verify gas type (natural/LP) before installation.

Installation Procedures

Step-by-step installation guide.

  1. Position unit: Level furnace on solid base or hanging brackets.
  2. Duct connections: Secure supply and return ducts with approved tape/clamps.
  3. Vent piping: Install according to manufacturer specifications.
  4. Drain lines: Connect condensate drain to proper disposal.
  5. Gas line: Install shutoff valve within 6 feet of unit.

WARNING! Use two people for lifting; unit weighs 85-120 lbs.

Electrical Connections

Wiring requirements and connections.

CAUTION! Disconnect power before making electrical connections.

Gas Connections

Gas line installation and pressure testing.

  1. Pipe sizing: Minimum 1/2" black iron pipe for natural gas
  2. Pressure test: Test at 14" WC for 10 minutes with no drop
  3. Manifold pressure: Natural gas 3.5" WC, LP gas 10" WC
  4. Leak check: Use soap solution on all connections
  5. Sediment trap: Install at gas inlet as required by code

WARNING! Gas connections must be made by qualified technician.

Venting Requirements

Proper vent system installation.

Vent TypeRequirements
PVCSchedule 40, minimum 2" diameter
CPVCApproved for high-efficiency applications
Stainless SteelAL29-4C for corrosive environments
Vent LengthMaximum 40 feet with two 90° elbows
Termination12" minimum above grade, away from windows

Startup and Commissioning

Initial startup procedure and system verification.

  1. Power on: Verify control board LED status
  2. Gas valve: Open main gas shutoff valve slowly
  3. Thermostat: Set to heat mode above room temperature
  4. Sequence: Observe ignition sequence and flame establishment
  5. Measurements: Verify gas pressure, temperature rise, CO levels

CAUTION! Never bypass safety controls during startup.

Operating Instructions

Normal operation and user controls.

Thermostat Settings: Programmable thermostat recommended for efficiency.

Operating Modes: Heat, Fan Only, Off. Blower delay adjustable 30-180 seconds.

Temperature Control: Maintain consistent temperature settings for optimal efficiency.

Fan Operation: Continuous fan mode available for air circulation.

Maintenance Schedule

Recommended maintenance intervals.

Tip: Keep maintenance records for warranty compliance.

Troubleshooting Guide

Common issues and solutions.

SymptomPossible CauseCorrective Action
No heatThermostat, power, gas supplyCheck thermostat setting, circuit breaker, gas valve
Short cyclingDirty filter, airflow restrictionReplace filter, check ductwork, verify temperature rise
Blower not runningMotor, capacitor, control boardCheck voltage to motor, test capacitor, inspect control board
Lockout conditionIgnition failure, flame sensorReset power, clean flame sensor, check gas pressure
Unusual noisesBlower wheel, inducer motorInspect for debris, check motor bearings, tighten components

Technical Specifications

Service: 1-800-SUBURBAN; www.suburbanmanufacturing.com

Suburban Furnace Installation Manual © - All Rights Reserved 2025