Summeraire Electric Furnace Manual

The Summeraire Electric Furnace is a high-efficiency heating system designed for residential and light commercial applications. Featuring advanced thermal technology, multiple heat stages, programmable thermostat compatibility, safety shut-off systems, and energy-saving modes. Operates on 240V AC power with variable blower speeds. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Thermostat 7. Operating Modes 8. Maintenance Schedule 9. Safety Features 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electric heating elements, multi-speed blower motor, control board, thermal limit switches, air filter compartment, thermostat connections.

FeatureDescription
Heating ElementsMultiple staged electric heating coils
Blower MotorVariable speed ECM motor for efficient airflow
Control BoardMicroprocessor-based control system
Thermal Limit SwitchesSafety shut-off for overheating protection
Air Filter CompartmentStandard 1-inch filter slot
Thermostat ConnectionsCompatible with most programmable thermostats
Power IndicatorLED status lights for system operation
Service SwitchLocal power disconnect switch
Drain ConnectionFor humidifier accessory installation
Access PanelsRemovable panels for maintenance access

Installation

Unpack and inspect contents. Ensure proper clearances and mounting surface.

  1. Position furnace: Place on stable, level surface with minimum 24-inch front clearance.
  2. Electrical connection: Connect 240V AC power supply with proper circuit breaker.
  3. Ductwork connection: Attach supply and return air ducts securely.
  4. Thermostat wiring: Connect thermostat wires to control board terminals.
  5. Install air filter: Insert standard 1-inch filter in filter compartment.

WARNING! Installation must be performed by qualified HVAC technician. Ensure proper electrical grounding.

First-Time Setup

Power on furnace; follow startup sequence.

  1. System check: Verify all connections are secure and proper.
  2. Thermostat configuration: Set heating mode and desired temperature.
  3. Blower speed adjustment: Set appropriate airflow for your duct system.
  4. Test operation: Run furnace through complete heating cycle.
  5. Safety verification: Confirm all safety switches function properly.

CAUTION! Do not bypass safety devices. Keep combustible materials away from furnace.

Specifications

Controls and Settings

Access control board via front access panel. LED status indicators show system operation.

Control Board: Power switch, diagnostic LEDs, dip switch settings, thermostat terminals.

Heating Stages: Multi-stage operation for efficiency. Blower Control: Adjustable delay timers and speeds. Temperature Limits: High limit safety switches. Diagnostic Mode: LED flash codes for troubleshooting. Dip Switches: Configuration for thermostat type, blower operation, staging.

Connecting Thermostat

Compatible with most 24V thermostats including programmable models.

  1. Turn off power at circuit breaker before wiring.
  2. Connect thermostat wires to control board terminals (R, W, G, Y, C).
  3. Configure dip switches for thermostat type (conventional or heat pump).
  4. Restore power and test thermostat operation.

Tip: Use 18-gauge thermostat wire for best performance.

Operating Modes

Multiple operating modes for efficiency and comfort.

  1. Heating Mode: Primary heating operation with staged heat.
  2. Fan Only: Continuous or intermittent blower operation.
  3. Emergency Heat: Manual override for maximum heating.
  4. Energy Saver: Reduced operation for energy conservation.
  5. Vacation Mode: Extended away settings for energy savings.

WARNING! Do not operate without proper airflow. Ensure filters are clean.

Maintenance Schedule

Regular maintenance ensures optimal performance and longevity.

FrequencyMaintenance Task
MonthlyCheck and replace air filter if dirty
SeasonalInspect electrical connections and components
AnnualProfessional inspection and cleaning
As NeededClean blower assembly and heat exchanger

CAUTION! Always disconnect power before performing maintenance.

Safety Features

Multiple safety systems protect against hazardous conditions.

Regulatory Information

UL Listed and certified to meet safety standards. Complies with NEC electrical codes and local building codes. Energy Star certified for high efficiency. Copyright © 2025 Summeraire Heating Systems; all rights reserved. For technical support, visit www.summeraire.com or contact 1-800-555-HEAT.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower supply/thermostatCheck circuit breaker; verify thermostat settings and batteries.
No heat outputHeating elements/limitsCheck for tripped limit switches; verify element operation.
Blower not runningMotor/capacitor/controlCheck blower motor; test capacitor; verify control board signals.
Frequent cyclingFilter/airflow/limitsReplace dirty filter; check for blocked vents; inspect limit switches.
Error codes flashingSystem faultsRefer to diagnostic chart in service manual; reset if applicable.

Reset: Turn power off for 30 seconds, then restore.

Service: 1-800-555-HEAT; www.summeraire.com

Summeraire Electric Furnace Manual © - All Rights Reserved 2025