The Thermo Scientific Thermolyne Furnace is a high-performance laboratory furnace designed for various heating applications including ashing, heat treating, annealing, and materials testing. Featuring precise temperature control, durable construction, and user-friendly operation, it is suitable for research, industrial, and educational environments. Below are key sections covering safety, features, installation, operation, maintenance, and troubleshooting.
Key components: High-temperature chamber, Digital temperature controller, Heating elements, Thermal insulation, Door safety switch, Power cord.
| Feature | Description |
|---|---|
| Temperature Range | Up to 1200°C (dependent on model) |
| Digital Controller | PID control with programmable settings |
| Chamber Dimensions | Varies by model (e.g., 6x6x6 inches) |
| Heating Elements | Kanthal or silicon carbide elements |
| Insulation | Ceramic fiber for efficient heat retention |
| Safety Features | Over-temperature protection, door interlock |
| Power Requirements | 120V/240V AC, 50/60Hz |
| Display | LED or LCD digital readout |
| Programmability | Multi-segment temperature profiles |
| Construction | Stainless steel exterior |
Unpack and inspect contents. Place on stable, heat-resistant surface.
WARNING! Furnace reaches extremely high temperatures; install away from combustible materials. Use heat-resistant gloves when handling.
Power on furnace; follow initial setup procedure.
CAUTION! Always wear appropriate personal protective equipment (PPE) when operating furnace.
Access control panel for temperature programming and monitoring.
Control Panel: POWER, TEMPERATURE SET, PROGRAM, ENTER, UP/DOWN arrows.
Temperature Settings: Set point, ramp rate, hold time. Safety: Over-temperature protection, door safety switch. Programs: Multi-segment profiles with ramp and soak functions. Display: Current temperature, set point, program status.
Standard operating procedure for furnace use.
Tip: Always pre-heat empty furnace to desired temperature before loading samples.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always disconnect power and allow furnace to cool completely before performing maintenance.
Over-temperature protection: Automatic shut-off if temperature exceeds set point. Door safety interlock: Prevents operation when door is open. Ground fault protection: Electrical safety circuit. Thermal insulation: Reduces exterior surface temperature.
Disconnect power and allow to cool completely before cleaning. Use soft brush or vacuum for chamber cleaning. Wipe exterior with damp cloth.
CAUTION! Never use water or chemical cleaners on hot surfaces. Avoid abrasive materials that could damage insulation.
UL/CSA certified for electrical safety. CE marked for European compliance. Manufactured in accordance with ISO 9001 quality standards. Copyright © Thermo Fisher Scientific. For technical support, visit www.thermofisher.com or contact 1-800-522-2255.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace not heating | Power supply/elements | Check power connection; inspect heating elements; verify controller settings. |
| Temperature inaccurate | Calibration/thermocouple | Recalibrate controller; check thermocouple connection. |
| Door won't lock | Safety interlock | Check door alignment; inspect interlock switch. |
| Error code displayed | Controller fault | Refer to error code in manual; reset controller. |
| Excessive heat loss | Insulation damage | Inspect chamber insulation; replace if damaged. |
Reset: Power cycle furnace; reset controller to factory defaults if needed.
Service: 1-800-522-2255; www.thermofisher.com