The Trane XV95 is a high-efficiency gas furnace with variable-speed technology, offering up to 95% AFUE efficiency. This two-stage furnace provides quiet operation, enhanced comfort control, and reliable heating performance. Below are key sections covering safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Variable-speed blower motor, two-stage gas valve, hot surface ignitor, induced draft motor, heat exchanger, and integrated control board.
| Feature | Description |
|---|---|
| Variable-speed blower | Provides consistent airflow and quiet operation |
| Two-stage gas valve | Adjusts heat output for optimal comfort and efficiency |
| Hot surface ignitor | Reliable electronic ignition system |
| Induced draft motor | Ensures proper venting and combustion |
| Stainless steel heat exchanger | Durable construction for long service life |
| Integrated control board | Monitors system operation and diagnostics |
| Pressure switches | Safety feature to verify proper venting |
| Flame sensor | Detects burner flame for safety shutdown |
| Limit switches | Prevents overheating |
| Filter monitoring | Alerts when filter needs replacement |
Professional installation required. Ensure proper clearances and venting.
WARNING! Gas furnace installation must be performed by qualified HVAC technician. Improper installation can cause fire, explosion, or carbon monoxide poisoning.
Initial startup and configuration by qualified technician.
CAUTION! Only qualified HVAC technicians should perform initial startup and adjustment procedures.
Integrated furnace control board with LED status indicator. Access via control panel cover.
Status Lights: Green (normal operation), Yellow (service required), Red (lockout condition).
Blower Speeds: Configurable for heating and cooling modes. Gas Valve: Two-stage operation (low/high fire). Limit Controls: Automatic high-temperature shutdown. Pressure Switches: Verify inducer operation and venting. Flame Sensor: Monitors burner operation. Diagnostic Codes: Flash patterns indicate specific issues.
Direct vent system using PVC pipe for intake and exhaust.
Tip: Keep vent terminals clear of snow, ice, and debris for proper operation.
Normal operation via thermostat control.
WARNING! Never block return or supply air registers. Maintain clear airflow paths.
Regular maintenance ensures optimal performance and safety.
CAUTION! Turn off electrical power and gas supply before performing any maintenance.
Multiple safety systems protect against hazardous conditions.
| Safety Feature | Function |
|---|---|
| Flame rollout switches | Detects improper burner combustion |
| High limit switches | Prevents overheating |
| Pressure switches | Verifies proper venting operation |
| Flame sensor | Ensures gas valve closes if no flame |
| Ignition control | Limited trial for ignition attempts |
| Gas valve | Automatic shutoff on safety lockout |
UL listed and ANSI certified. Complies with applicable safety standards. Manufactured to meet or exceed industry requirements for residential gas furnaces. For technical support, contact Trane Residential Solutions at 1-800-554-6413 or visit www.trane.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, safety lockout | Check circuit breaker; verify thermostat setting; check status lights |
| No heat | Gas supply, ignitor, flame sensor | Verify gas valve on; check for spark at ignitor; clean flame sensor |
| Short cycling | Dirty filter, blocked vents, limit switch | Replace filter; clear vents; check airflow restrictions |
| Blower not running | Motor, capacitor, control board | Check for power to blower; inspect capacitor; verify control signals |
| Unusual noises | Motor bearings, blower wheel, inducer | Lubricate if applicable; check for obstructions; tighten components |
| Lockout condition | Safety device activation | Reset power; check diagnostic lights; call for service if persistent |
Reset Procedure: Turn power off for 30 seconds, then restore.
Service: 1-800-554-6413; www.trane.com