WaterFurnace 5 Series Manual

The WaterFurnace 5 Series is a high-efficiency geothermal heat pump system designed for residential and light commercial applications. This advanced system provides both heating and cooling capabilities with superior energy efficiency, utilizing ground-source heat exchange technology. Below are key sections covering safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation Guidelines 3. Initial Setup 4. Technical Specifications 5. Controls and Settings 6. System Operation 7. Maintenance Procedures 8. Performance Optimization 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting Guide

Features at a Glance

Key components: Advanced compressor technology, dual-capacity operation, smart grid ready, variable speed blower, and integrated control system.

FeatureDescription
Compressor TechnologyTwo-stage scroll compressor for enhanced efficiency
Dual-Capacity OperationAutomatic adjustment between high and low stages
Smart Grid ReadyCompatible with utility demand response programs
Variable Speed BlowerECM motor for precise airflow control
Control SystemIntuitive touchscreen interface with advanced diagnostics
Heat ExchangerStainless steel construction for durability
RefrigerantR-410A environmentally friendly refrigerant
Sound InsulationAdvanced sound-dampening technology
Water LoopCorrosion-resistant heat exchanger
Thermostat InterfaceCompatible with most modern thermostats

Installation Guidelines

Professional installation required. Ensure proper site preparation and system compatibility.

  1. Site Preparation: Level concrete pad or suspended mounting
  2. Loop Field Connection: Connect ground loop piping with proper insulation
  3. Electrical Connection: 208/230V single-phase power supply
  4. Ductwork Connection: Properly sized and sealed duct system
  5. Water Connections: Install isolation valves and flow control devices
  6. Control Wiring: Connect thermostat and system controls

WARNING! Installation must be performed by qualified HVAC technician. Electrical shock hazard exists.

Initial Setup

Power on system and configure initial settings through control interface.

  1. System Power: Turn on main electrical disconnect
  2. Control Setup: Configure date, time, and system preferences
  3. Thermostat Programming: Set heating/cooling setpoints and schedules
  4. Mode Selection: Choose heating, cooling, or auto mode
  5. Temperature Calibration: Verify sensor accuracy
  6. Test Operation: Run system through complete cycle

CAUTION! Allow system to complete initial startup sequence without interruption.

Technical Specifications

Controls and Settings

Access system controls through touchscreen interface or compatible thermostat.

Control Panel: POWER, MODE, FAN, TEMP UP/DOWN, MENU, ENTER.

System Settings: Operating mode (Heat/Cool/Auto), temperature setpoints, fan speed (Auto/Low/Med/High), schedule programming, system lockout, diagnostic codes. Advanced Settings: Compressor delay timers, auxiliary heat lockout, circulation pump control, smart grid settings.

System Operation

Automatic operation with manual override capabilities.

  1. Startup: System performs self-check before operation
  2. Heating Mode: Extracts heat from ground loop
  3. Cooling Mode: Rejects heat to ground loop
  4. Dual-Stage Operation: Automatically adjusts capacity
  5. Auxiliary Heat: Supplemental electric heat when needed
  6. Defrost Cycle: Automatic in heating mode

Tip: Maintain consistent temperature settings for optimal efficiency.

Maintenance Procedures

Regular maintenance ensures optimal performance and longevity.

  1. Monthly: Check air filters, clean if necessary
  2. Quarterly: Inspect condensate drain system
  3. Annually: Professional inspection and service
  4. Seasonal: Check loop pressure and antifreeze concentration
  5. Biannual: Clean blower wheel and evaporator coil
  6. As Needed: Calibrate sensors and controls

WARNING! Disconnect power before performing any maintenance.

Performance Optimization

Maximize system efficiency through proper settings and maintenance.

Care & Maintenance

Regular care extends system life and maintains efficiency.

Keep unit clear of debris and vegetation. Clean air filters monthly. Schedule annual professional maintenance. Monitor system performance indicators.

CAUTION! Do not attempt to service refrigerant system. Contact qualified technician.

Regulatory Information

UL Certified to UL 1995. Meets DOE energy efficiency standards. EPA compliant refrigerant usage. AHRI certified performance ratings. Manufactured in accordance with ISO 9001 quality standards. For technical support, visit www.waterfurnace.com or contact 1-800-222-4524.

Troubleshooting Guide

SymptomPossible CauseCorrective Action
No heating/coolingPower loss, thermostat issueCheck circuit breaker, verify thermostat settings
Poor performanceDirty filters, low airflowClean/replace filters, check ductwork
Unusual noisesLoose components, bearing wearInspect blower assembly, contact technician
High energy usageDirty coils, incorrect settingsClean coils, verify thermostat programming
Error codes displayedSystem fault, sensor failureReference code in manual, contact service

Reset: Power cycle system or use reset button if equipped.

Service: 1-800-222-4524; www.waterfurnace.com

WaterFurnace 5 Series Manual © - All Rights Reserved 2025