The York Affinity 9 V Series is a high-efficiency gas furnace featuring variable-speed technology, AFUE ratings up to 98%, quiet operation, durable heat exchanger construction, advanced diagnostic controls, multi-speed blower motor, direct spark ignition, and compatibility with various thermostat systems. Designed for residential heating applications with natural gas or propane capability. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Variable-speed ECM blower motor, aluminized steel heat exchanger, integrated control board, pressure switches, gas valve, igniter, flame sensor, condensate drain system.
| Feature | Description |
|---|---|
| Variable-speed blower | Provides consistent airflow and quiet operation |
| Aluminized steel heat exchanger | Durable corrosion-resistant construction |
| Integrated control board | Advanced diagnostics and system monitoring |
| Direct spark ignition | Reliable ignition system |
| Pressure switches | Safety verification of venting operation |
| Flame sensor | Monitors burner operation |
| Condensate drain system | Removes combustion byproducts |
| Multi-position installation | Upflow, downflow, or horizontal configurations |
| Communication capability | Compatible with advanced thermostat systems |
| Service light indicators | LED diagnostic codes for troubleshooting |
Proper installation requires qualified HVAC technician. Verify local codes and obtain permits.
WARNING! Gas furnaces produce carbon monoxide; proper venting is critical. Installation by unqualified personnel may create hazardous conditions.
Initial startup must be performed by qualified technician.
CAUTION! Never bypass safety controls. Verify proper operation before leaving installation.
Integrated control board manages all furnace operations with LED status indicators.
Control Board Features: Self-diagnostic capability, status light codes, communication terminal, safety lockout, variable-speed control.
Operation Sequence: Thermostat call for heat, inducer motor start, pressure switch verification, igniter activation, gas valve opening, flame sensor verification, blower activation. Normal shutdown: Gas valve closes, blower continues for post-purge cycle.
Proper venting is critical for safe operation and efficiency.
Tip: Regular inspection of vent pipes for blockage or deterioration is essential.
Annual maintenance by qualified technician recommended.
WARNING! Turn off electrical power and gas supply before performing any maintenance.
Multiple safety systems protect against hazardous conditions: Flame rollout switches, high limit switches, pressure switches, flame sensor, igniter control, lockout protection, condensate overflow switch.
Regular maintenance ensures optimal performance and longevity.
CAUTION! Use only manufacturer-approved replacement parts. Keep area around furnace clean and free of combustible materials. Never store chemicals or flammable materials near furnace.
UL certified for safety standards. Complies with ANSI Z21.47 standards for gas-fired central furnaces. CSA certified for Canadian installations. Manufactured to meet or exceed DOE energy efficiency standards. For technical support, contact York International at 1-800-910-YORK or visit www.york.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, safety lockout | Check circuit breaker, thermostat setting, reset if locked out. |
| No heat | Gas supply, igniter, flame sensor | Verify gas valve on, check for spark, clean flame sensor. |
| Short cycling | Dirty filter, blocked vent, high limit | Replace filter, check venting, verify proper airflow. |
| Blower won't run | Motor, capacitor, control board | Check power to motor, test capacitor, verify control signal. |
| Unusual noises | Blower, inducer, heat exchanger | Inspect for loose components, clean blower wheel, check heat exchanger. |
Reset: Power cycle furnace at disconnect or circuit breaker.
Service: 1-800-910-YORK; www.york.com